Determination of the D-amino acid content in foods and in biological samples is a very important task. In order to achieve this goal we developed a biosensor employing the flavoenzyme D-amino acid oxidase from the yeast Rhodotorula gracilis. To produce a device in which the D-amino acid composition does not alter the results, both the wild-type and a number of mutants obtained by rational design and directed evolution approaches were used. An analysis of D-amino acid oxidase mutants activity on D-amino acid mixtures containing various ratios of neutral, acidic, and basic substrates identified the Amberzyme-immobilized T60A/Q144R/K152E and M213G mutants as the best choice: their response shows an only limited dependence on the solution composition when at least 20% of the D-amino acid is made up of D-alanine (standard error is approximately 5-9%). This is the first report, to our knowledge, demonstrating that the entire D-amino acid content can be determined by using a screen-printed electrode amperometric biosensor, with a detection limit of 0.25 mM and a mean response time of 10-15 min. The D-amino acid assay based on R. gracilis DAAO-biosensor is inexpensive, simple to perform, and rapid: the D-amino acid concentration of a variety of biological samples can be investigated using this assay.

A biosensor for all D-amino acids using evolved D-amino acid oxidase

ROSINI, ELENA;MOLLA, GIANLUCA;ROSSETTI, CARLO;PILONE, MIRELLA;POLLEGIONI, LOREDANO;SACCHI, SILVIA
2008-01-01

Abstract

Determination of the D-amino acid content in foods and in biological samples is a very important task. In order to achieve this goal we developed a biosensor employing the flavoenzyme D-amino acid oxidase from the yeast Rhodotorula gracilis. To produce a device in which the D-amino acid composition does not alter the results, both the wild-type and a number of mutants obtained by rational design and directed evolution approaches were used. An analysis of D-amino acid oxidase mutants activity on D-amino acid mixtures containing various ratios of neutral, acidic, and basic substrates identified the Amberzyme-immobilized T60A/Q144R/K152E and M213G mutants as the best choice: their response shows an only limited dependence on the solution composition when at least 20% of the D-amino acid is made up of D-alanine (standard error is approximately 5-9%). This is the first report, to our knowledge, demonstrating that the entire D-amino acid content can be determined by using a screen-printed electrode amperometric biosensor, with a detection limit of 0.25 mM and a mean response time of 10-15 min. The D-amino acid assay based on R. gracilis DAAO-biosensor is inexpensive, simple to perform, and rapid: the D-amino acid concentration of a variety of biological samples can be investigated using this assay.
2008
Rosini, Elena; Molla, Gianluca; Rossetti, Carlo; Pilone, Mirella; Pollegioni, Loredano; Sacchi, Silvia
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1707772
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 42
social impact