Background: Currently, training in interventional electrophysiology is based on conventional methodologies, and a paucity of data on the usefulness of simulation in this field is available. Objective: The purpose of this study was to evaluate the impact of simulator training on trainees' performance in electrophysiologic catheter placement during the early phase of their learning curve. Methods: Inexperienced electrophysiology fellows were considered. A hybrid high-fidelity simulator (Procedicus VIST, version 7.0, Mentice AB Gothenburg, Sweden for Biosense Webster) was used. The following parameters were evaluated in 3 consecutive patient-based procedures before and after two training sessions of at least 1.5 hours on the simulator: (1) ability to place catheters in conventional recording/pacing sites (coronary sinus, His-bundle area, high right atrium, and right ventricular apex); (2) amount of help provided by the supervisor (scale from 1-3; 3 for maximal help); (3) fluoroscopy time; and (4) positioning time. Results: Seven fellows performed 168 catheter placements during 42 patient-based procedures with no complications. Comparing parameters before and after simulator training, there was a significant reduction in the mean amount of help and in fluoroscopy and positioning times per placement: from 1.71 ± 1.24 to 0.42 ± 0.68 (P <.001), from 121 ± 88 seconds to 76 ± 54 seconds (P <.001), and from 175 ± 138 seconds to 102 ± 74 seconds (P <.001), respectively. Overall fluoroscopy time per patient decreased from 567 ± 220 seconds to 305 ± 111 seconds (P <.0001). Improvement appeared to be related to simulator training alone and not to the previously performed patient-based procedures. Conclusion: During the early phase of the trainees' learning curve, simulator training significantly improves the independent trainees' performance with reduction in radiation exposure.

BACKGROUND Currently, training in interventional electrophysiology is based on conventional methodologies, and a paucity of data on the usefulness of simulation in this field is available.OBJECTIVE The purpose of this study was to evaluate the impact of simulator training on trainees' performance in electrophysiologic catheter placement during the early phase of their learning curve.METHODS Inexperienced electrophysiology fellows were considered. A hybrid high-fidelity simulator (Procedicus VIST, version 7.0, Mentice AB Gothenburg, Sweden for Biosense Webster) was used. The following parameters were evaluated in 3 consecutive patient-based procedures before and after two training sessions of at least 1.5 hours on the simulator: (1) ability to place catheters in conventional recording/pacing sites (coronary sinus, His-bundle area, high right atrium, and right ventricular apex); (2) amount of help provided by the supervisor (scale from 1-3; 3 for maximal help); (3) fluoroscopy time; and (4) positioning time.RESULTS Seven fellows performed 168 catheter placements during 42 patient-based procedures with no complications. Comparing parameters before and after simulator training, there was a significant reduction in the mean amount of help and in fluoroscopy and positioning times per placement: from 1.71 +/- 1.24 to 0.42 +/- 0.68 (P < .001), from 121 +/- 88 seconds to 76 +/- 54 seconds (P < .001), and from 175 +/- 138 seconds to 102 +/- 74 seconds (P < .001), respectively. Overall fluoroscopy time per patient decreased from 567 +/- 220 seconds to 305 +/- 111 seconds (P < .0001). Improvement appeared to be related to simulator training alone and not to the previously performed patient-based procedures.CONCLUSION During the early phase of the trainees' learning curve, simulator training significantly improves the independent trainees' performance with reduction in radiation exposure.

Simulator training reduces radiation exposure and improves trainees' performance in placing electrophysiologic catheters during patient-based procedures

DE PONTI, ROBERTO;SALERNO URIARTE, JORGE ANTONIO
2012-01-01

Abstract

BACKGROUND Currently, training in interventional electrophysiology is based on conventional methodologies, and a paucity of data on the usefulness of simulation in this field is available.OBJECTIVE The purpose of this study was to evaluate the impact of simulator training on trainees' performance in electrophysiologic catheter placement during the early phase of their learning curve.METHODS Inexperienced electrophysiology fellows were considered. A hybrid high-fidelity simulator (Procedicus VIST, version 7.0, Mentice AB Gothenburg, Sweden for Biosense Webster) was used. The following parameters were evaluated in 3 consecutive patient-based procedures before and after two training sessions of at least 1.5 hours on the simulator: (1) ability to place catheters in conventional recording/pacing sites (coronary sinus, His-bundle area, high right atrium, and right ventricular apex); (2) amount of help provided by the supervisor (scale from 1-3; 3 for maximal help); (3) fluoroscopy time; and (4) positioning time.RESULTS Seven fellows performed 168 catheter placements during 42 patient-based procedures with no complications. Comparing parameters before and after simulator training, there was a significant reduction in the mean amount of help and in fluoroscopy and positioning times per placement: from 1.71 +/- 1.24 to 0.42 +/- 0.68 (P < .001), from 121 +/- 88 seconds to 76 +/- 54 seconds (P < .001), and from 175 +/- 138 seconds to 102 +/- 74 seconds (P < .001), respectively. Overall fluoroscopy time per patient decreased from 567 +/- 220 seconds to 305 +/- 111 seconds (P < .0001). Improvement appeared to be related to simulator training alone and not to the previously performed patient-based procedures.CONCLUSION During the early phase of the trainees' learning curve, simulator training significantly improves the independent trainees' performance with reduction in radiation exposure.
2012
DE PONTI, Roberto; Marazzi, R; Doni, La; Tamborini, C; Ghiringhelli, S; SALERNO URIARTE, JORGE ANTONIO
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1888323
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 38
social impact