Background: We hypothesized that a negative microvolt T-wave alternans (MTWA) test would identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillator (ICD) therapy in a prospective cohort. Methods and Results: Data were pooled from 8 centers where MTWA testing was performed specifically for the purpose of guiding primary prevention ICD implantation. Cohorts were included if the ratio of ICDs implanted in patients who were MTWA "non-negative" to patients who were MTWA negative was >2:1, indicating that MTWA testing had a significant impact on the decision to implant an ICD. The pooled cohort included 651 patients: 371 MTWA non-negative and 280 MTWA negative. Among non-negative patients, 62% underwent ICD implantation whereas only 13% of MTWA-negative patients received an ICD (P<0.01). Despite a substantially lower prevalence of ICDs, long-term survival (6.9 years) was significantly better among MTWA-negative patients (68.2% non-negative vs. 87.1% negative, P=0.026). Conclusions: MTWA-negative patients had significantly better survival than MTWA non-negative patients, the majority of whom had ICDs. Despite a very low prevalence of ICDs, long-term survival among patients with left ventricular ejection fraction ≤40% and a negative MTWA test was better than in the ICD arm of any study to date that has demonstrated a benefit of ICDs. This provides further evidence that MTWA-negative patients are unlikely to benefit from primary prevention ICD therapy.

Prospective use of microvolt T-wave alternans testing to guide primary prevention implantable cardioverter defibrillator therapy

SALERNO URIARTE, JORGE ANTONIO;
2015-01-01

Abstract

Background: We hypothesized that a negative microvolt T-wave alternans (MTWA) test would identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillator (ICD) therapy in a prospective cohort. Methods and Results: Data were pooled from 8 centers where MTWA testing was performed specifically for the purpose of guiding primary prevention ICD implantation. Cohorts were included if the ratio of ICDs implanted in patients who were MTWA "non-negative" to patients who were MTWA negative was >2:1, indicating that MTWA testing had a significant impact on the decision to implant an ICD. The pooled cohort included 651 patients: 371 MTWA non-negative and 280 MTWA negative. Among non-negative patients, 62% underwent ICD implantation whereas only 13% of MTWA-negative patients received an ICD (P<0.01). Despite a substantially lower prevalence of ICDs, long-term survival (6.9 years) was significantly better among MTWA-negative patients (68.2% non-negative vs. 87.1% negative, P=0.026). Conclusions: MTWA-negative patients had significantly better survival than MTWA non-negative patients, the majority of whom had ICDs. Despite a very low prevalence of ICDs, long-term survival among patients with left ventricular ejection fraction ≤40% and a negative MTWA test was better than in the ICD arm of any study to date that has demonstrated a benefit of ICDs. This provides further evidence that MTWA-negative patients are unlikely to benefit from primary prevention ICD therapy.
2015
https://www.jstage.jst.go.jp/article/circj/79/9/79_CJ-15-0253/_pdf
Implantable cardioverter defibrillator; Microvolt T wave alternans; Primary prevention; Risk stratification; Sudden cardiac death; Adult; Aged; Aged, 80 and over; Arrhythmias, Cardiac; Disease-Free Survival; Female; Follow-Up Studies; Humans; Male; Middle Aged; Prospective Studies; Survival Rate; Defibrillators, Implantable; Electric Countershock; Cardiology and Cardiovascular Medicine
Merchant, Faisal M; SALERNO URIARTE, JORGE ANTONIO; Caravati, Fabrizio; Falcone, Stefania; Molon, Giulio; Marangoni, Daniele; Raczak, Grzegorz; Danilowicz Szymanowicz, Ludmila; Pedretti, Roberto F. E.; Braga, Simona Sarzi; Ikeda, Takanori; Calo, Leonardo; Martino, Annamaria; Erciyes, Demet; Piancastelli, Maurizio; Maury, Philippe; Cohen, Richard J.; Armoundas, Antonis A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2062128
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact