Abstract The aims of this study were to (1) record the changes of (arterial oxygen partial pressure) PaO2, (arterial carbon dioxide partial pressure) PaCO2, (percentage saturation of haemoglobin with oxygen in arterial blood) SaO2 and alveolar-arterial (A-a) oxygen gradiant resulting from bronchoalveolar lavage (BAL) in asthmatic and normal subjects; (2) measure changes in forced expiratory volume in 1 s (FEV1), vital capacity forced (FVC) associated with BAL; and (3) assess possible predictive factors for the degree of hypoxaemia and impairment of spirometry resulting from BAL. Bronchoscopy and BAL (150 ml) were performed in 24 asthmatics and 15 healthy subjects. Serial arterial blood samples (radial artery) were obtained in all subjects: T1 and before T2 after local anaesthesia; T3 at end of bronchoscopy; T4 after BAL and 5 min, 15 min, 1 h, 2 h, 8 h and 24 h (T5-T10) after the procedure, FEV1 and FVC were measured immediately before and 5 min afer bronchoscopy. Baseline PaO2 was lower in asthmatics (10.2 +/- 0.8 kPa) than in healthy subjects (10.8 +/- 0.8). Both groups showed a significant decrease in PaO2, and a significant widening in (A-a) oxygen tension gradiant at T3-9, with respect to T1 (P < 0.05). PaO2 reached a significantly lower value in asthmatics (7.1 +/- 0.6 kPa) than in HS (7.7 +/- 0.5; P < 0.05). In asthmatics, FEV1, FVC and the ratio FEV1/FVC decreased significantly after BAL (P < 0.001). In healthy subjects, FEV1 and FVC decreased significantly (P < 0.001), whereas FEV1/FVC did not. The fall in FEV1 after BAL was significantly greater in asthmatics (32.4 +/- 10.0%) than in healthy subjects (17.7 +/- 4.6; P < 0.001). Severity of asthma, basline FEV1 or initial PaO2 did not predict the degree of hypoxaemia or the fall of FEV1. It is concluded that BAL causes more severe hypoxaemia and a greater decrease in FEV1 in asthmatics compared to healthy subjects, strongly supporting the recommendation of special caution and careful monitoring when BAL is undertaken in asthmatics.

Bronchoalveolar lavage causes decrease in PaO2, increase in (A-a) gradient value and bronchoconstriction in asthmatics.

SPANEVELLO, ANTONIO;
1998-01-01

Abstract

Abstract The aims of this study were to (1) record the changes of (arterial oxygen partial pressure) PaO2, (arterial carbon dioxide partial pressure) PaCO2, (percentage saturation of haemoglobin with oxygen in arterial blood) SaO2 and alveolar-arterial (A-a) oxygen gradiant resulting from bronchoalveolar lavage (BAL) in asthmatic and normal subjects; (2) measure changes in forced expiratory volume in 1 s (FEV1), vital capacity forced (FVC) associated with BAL; and (3) assess possible predictive factors for the degree of hypoxaemia and impairment of spirometry resulting from BAL. Bronchoscopy and BAL (150 ml) were performed in 24 asthmatics and 15 healthy subjects. Serial arterial blood samples (radial artery) were obtained in all subjects: T1 and before T2 after local anaesthesia; T3 at end of bronchoscopy; T4 after BAL and 5 min, 15 min, 1 h, 2 h, 8 h and 24 h (T5-T10) after the procedure, FEV1 and FVC were measured immediately before and 5 min afer bronchoscopy. Baseline PaO2 was lower in asthmatics (10.2 +/- 0.8 kPa) than in healthy subjects (10.8 +/- 0.8). Both groups showed a significant decrease in PaO2, and a significant widening in (A-a) oxygen tension gradiant at T3-9, with respect to T1 (P < 0.05). PaO2 reached a significantly lower value in asthmatics (7.1 +/- 0.6 kPa) than in HS (7.7 +/- 0.5; P < 0.05). In asthmatics, FEV1, FVC and the ratio FEV1/FVC decreased significantly after BAL (P < 0.001). In healthy subjects, FEV1 and FVC decreased significantly (P < 0.001), whereas FEV1/FVC did not. The fall in FEV1 after BAL was significantly greater in asthmatics (32.4 +/- 10.0%) than in healthy subjects (17.7 +/- 4.6; P < 0.001). Severity of asthma, basline FEV1 or initial PaO2 did not predict the degree of hypoxaemia or the fall of FEV1. It is concluded that BAL causes more severe hypoxaemia and a greater decrease in FEV1 in asthmatics compared to healthy subjects, strongly supporting the recommendation of special caution and careful monitoring when BAL is undertaken in asthmatics.
1998
BRONCHIAL RESPONSIVENESS, FIBEROPTIC BRONCHOSCOPY, BIOPSY, SAFETY
Spanevello, Antonio; Migliori, Gb; Satta, A; Sharara, A; Ballardini, L; Ind, Pw; Neri, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/12755
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 16
social impact