PURPOSE: The incidence of iatrogenic femoral artery pseudoaneurysms is reported to occur in 1-7% by of all percutaneous catheterisations. These pseudoaneurysms are traditionally treated by ultrasound-guided compression or surgical repair. We report our experience in sealing postcatheterization femoral pseudoaneurysms with percutaneous thrombin injection under colour-Doppler ultrasound guidance. MATERIALS AND METHODS: Since June 2000 we have consecutively treated 31 pseudoaneurysms in 30 patients, (14 males and 16 females, age range 45 to 81 years); in one patient the pseudoaneurysm was bilateral. All patients had a clinical diagnosis of postcatheterization femoral pseudoaneurysm, later confirmed by colour-Doppler ultrasonography. We injected a bovine thrombin solution percutaneously at a concentration of 1000 U/mL using 21-22 gauge needles under colour Doppler ultrasound guidance. All patients underwent clinical and colour-Doppler US examination before, during and 24 hours after the procedure and were followed up after 1 and 3 months. RESULTS: The primary success rate was 83.8%. Complete and persistent occlusion of the pseudoaneurysm was achieved in less than 20 seconds by administering an average dose of 880 U of thrombin (0.8 mL of solution). In 5 cases (16.1%) reperfusion of the pseudoaneurysm was observed within 24 hours. These patients underwent a repeat procedure. The final result was successful in 96.7% of patients (30 of 31 cases). No thromboembolic complication was observed. Only 22.5% of patients reported a heat sensation in the treated limb, which resolved spontaneously within minutes. CONCLUSIONS: The percutaneous injection of thrombin under ultrasound colour-Doppler guidance should be regarded as the first choice treatment for postcatheterization femoral pseudoaneurysms, owing to its simplicity, safety, effectiveness and inexpensiveness.

Occlusion of postcatheterisation femoral pseudoaneurysms with percutaneous thrombin injection under ultrasound guidance

CARRAFIELLO, GIANPAOLO;
2004-01-01

Abstract

PURPOSE: The incidence of iatrogenic femoral artery pseudoaneurysms is reported to occur in 1-7% by of all percutaneous catheterisations. These pseudoaneurysms are traditionally treated by ultrasound-guided compression or surgical repair. We report our experience in sealing postcatheterization femoral pseudoaneurysms with percutaneous thrombin injection under colour-Doppler ultrasound guidance. MATERIALS AND METHODS: Since June 2000 we have consecutively treated 31 pseudoaneurysms in 30 patients, (14 males and 16 females, age range 45 to 81 years); in one patient the pseudoaneurysm was bilateral. All patients had a clinical diagnosis of postcatheterization femoral pseudoaneurysm, later confirmed by colour-Doppler ultrasonography. We injected a bovine thrombin solution percutaneously at a concentration of 1000 U/mL using 21-22 gauge needles under colour Doppler ultrasound guidance. All patients underwent clinical and colour-Doppler US examination before, during and 24 hours after the procedure and were followed up after 1 and 3 months. RESULTS: The primary success rate was 83.8%. Complete and persistent occlusion of the pseudoaneurysm was achieved in less than 20 seconds by administering an average dose of 880 U of thrombin (0.8 mL of solution). In 5 cases (16.1%) reperfusion of the pseudoaneurysm was observed within 24 hours. These patients underwent a repeat procedure. The final result was successful in 96.7% of patients (30 of 31 cases). No thromboembolic complication was observed. Only 22.5% of patients reported a heat sensation in the treated limb, which resolved spontaneously within minutes. CONCLUSIONS: The percutaneous injection of thrombin under ultrasound colour-Doppler guidance should be regarded as the first choice treatment for postcatheterization femoral pseudoaneurysms, owing to its simplicity, safety, effectiveness and inexpensiveness.
2004
Corso, R.; Rampoldi, A.; Riolo, F.; Carrafiello, Gianpaolo; Solcia, M.; Intotero, M.; Vanzulli, A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1491621
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 3
social impact