Metabolic surveillance of the myocardium is of great interest in cardiac surgery. Microdialysis allows sampling of chemical substances from the interstitial fluid for immediate analysis. The two objectives of this study were to develop a technique for simple and safe implantation of a commercially available microdialysis probe (CMA-70) into the myocardium and to obtain reference data for further use and metabolic control. Eighteen pigs were used in an experimental ischaemic heart model where the left anterior descending coronary artery was occluded for 20 min. Microdialysis was performed proximally as well as distally to the arterial occlusion site corresponding to a control and an ischaemic area in the heart. Two techniques were tried for probe implantation, using either a pacemaker wire attached to the probe tip or a needle introducer. Metabolic substrates (glucose, lactate, glycerol and pyruvate) were collected before, during and after ischaemia, for up to 6 h. Both techniques were highly effective in registering metabolic changes due to ischaemia with sharp time resolution, but the needle introducer was superior regarding probe durability. It is concluded that the CMA-70 microdialysis probe implanted with the needle introducer allows for an accurate monitoring of myocardial metabolism during a prolonged period of time. Future studies in the human heart are warranted to further validate the technique.

Microdialysis for myocardial metabolic surveillance: developing a clinical technique

MANTOVANI, VITTORIO;SALA, ANDREA ANTONIO;
2006-01-01

Abstract

Metabolic surveillance of the myocardium is of great interest in cardiac surgery. Microdialysis allows sampling of chemical substances from the interstitial fluid for immediate analysis. The two objectives of this study were to develop a technique for simple and safe implantation of a commercially available microdialysis probe (CMA-70) into the myocardium and to obtain reference data for further use and metabolic control. Eighteen pigs were used in an experimental ischaemic heart model where the left anterior descending coronary artery was occluded for 20 min. Microdialysis was performed proximally as well as distally to the arterial occlusion site corresponding to a control and an ischaemic area in the heart. Two techniques were tried for probe implantation, using either a pacemaker wire attached to the probe tip or a needle introducer. Metabolic substrates (glucose, lactate, glycerol and pyruvate) were collected before, during and after ischaemia, for up to 6 h. Both techniques were highly effective in registering metabolic changes due to ischaemia with sharp time resolution, but the needle introducer was superior regarding probe durability. It is concluded that the CMA-70 microdialysis probe implanted with the needle introducer allows for an accurate monitoring of myocardial metabolism during a prolonged period of time. Future studies in the human heart are warranted to further validate the technique.
2006
Mantovani, Vittorio; Kennergren, C; Goiny, M; Ungerstedt, U; Lonnroth, P; Sala, ANDREA ANTONIO; Berglin, E.
File in questo prodotto:
File Dimensione Formato  
Mantovani1.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 251.88 kB
Formato Adobe PDF
251.88 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1499508
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 15
social impact