OBJECTIVES We report the data from the Italian Survey on trans-septal catheterization (TSP-C) for catheter ablation of arrhythmias in the left heart that covered 2003 and previous years. BACKGROUND Over the last decade the use of TSP-C in the electrophysiology laboratory has greatly increased. Recent data on number of procedures, accomplishment rate, and complications related to this procedure are lacking in a large cohort of patients. METHODS Thirty-three centers participated in the survey. The data collected retrospectively for 2003 included the number of procedures, indications, methods, and the number and reason for unaccomplished cases along with complications. Retrospective data collected for previous years included the annual number of procedures and cumulative data concerning indications, accomplishments, and complications. RESULTS Since 1992, 5,520 TSP-C procedures were used in arrhythmia ablation, with the peak increase in the use occurring in 2001. Trans-septal catheterization was performed for atrial fibrillation (AF) ablation in 78.3% of the procedures in 2003. The electrophysiologist independently performed the procedure in 29 of 33 centers. Trans-septal catheterization was successfully performed in 99.1% of the cases; the main reason for TSP-C not being performed was related to fossa ovalis/atrial septum anatomy. Complications were low both in 2003 and in the previous years (0.79% and 0.74%, respectively). CONCLUSIONS Trans-septal catheterization in the electrophysiology laboratory is associated with a high success and low complication rate. The use of TSP-C has progressively increased over the last decade and is currently used primarily for AF ablation. Although possible, severe complications were rare.

Trans-septal catheterization in the electrophysiology laboratory: data from a multicentre survey spanning 12 years

DE PONTI, ROBERTO;SALERNO URIARTE, JORGE ANTONIO
2006-01-01

Abstract

OBJECTIVES We report the data from the Italian Survey on trans-septal catheterization (TSP-C) for catheter ablation of arrhythmias in the left heart that covered 2003 and previous years. BACKGROUND Over the last decade the use of TSP-C in the electrophysiology laboratory has greatly increased. Recent data on number of procedures, accomplishment rate, and complications related to this procedure are lacking in a large cohort of patients. METHODS Thirty-three centers participated in the survey. The data collected retrospectively for 2003 included the number of procedures, indications, methods, and the number and reason for unaccomplished cases along with complications. Retrospective data collected for previous years included the annual number of procedures and cumulative data concerning indications, accomplishments, and complications. RESULTS Since 1992, 5,520 TSP-C procedures were used in arrhythmia ablation, with the peak increase in the use occurring in 2001. Trans-septal catheterization was performed for atrial fibrillation (AF) ablation in 78.3% of the procedures in 2003. The electrophysiologist independently performed the procedure in 29 of 33 centers. Trans-septal catheterization was successfully performed in 99.1% of the cases; the main reason for TSP-C not being performed was related to fossa ovalis/atrial septum anatomy. Complications were low both in 2003 and in the previous years (0.79% and 0.74%, respectively). CONCLUSIONS Trans-septal catheterization in the electrophysiology laboratory is associated with a high success and low complication rate. The use of TSP-C has progressively increased over the last decade and is currently used primarily for AF ablation. Although possible, severe complications were rare.
2006
DE PONTI, Roberto; Cappato, R.; Curnis, A.; Della Bella, P.; Padeletti, L.; Raviele, A.; Santini, M.; SALERNO URIARTE, JORGE ANTONIO
File in questo prodotto:
File Dimensione Formato  
JACC_2006_47_5.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 205.48 kB
Formato Adobe PDF
205.48 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1708441
Citazioni
  • ???jsp.display-item.citation.pmc??? 34
  • Scopus 199
  • ???jsp.display-item.citation.isi??? 152
social impact