Safe operating conditions, for strongly exothermic chemical systems involving multiple reactions, are particularly critical to be obtained, because of the complex interactions between selectivity and safety constraints. In this work, new criteria, which are useful for isoperibolic semibatch processes involving consecutive reactions and based on the topology of a particular phase space, are presented. Such criteria are able to detect both the runaway boundary and the so-called “quick onset, fair conversion, smooth temperature profile” (QFS) operating region by performing a topological analysis of the phase space of the system of ordinary differential equations (ODEs) that describe the analyzed process. Moreover, a safe optimization procedure, the objective of which is to obtain the optimum values both of the dosing time of the dosed reactant and the initial reactor temperature, based on such criteria, has been developed. Finally, such a set of optimum operating parameters has been validated through a comparison with experimental data from published literature.

Topological criteria to safely optimize hazardous chemical processes involving consecutive reactions

COPELLI, SABRINA;
2010-01-01

Abstract

Safe operating conditions, for strongly exothermic chemical systems involving multiple reactions, are particularly critical to be obtained, because of the complex interactions between selectivity and safety constraints. In this work, new criteria, which are useful for isoperibolic semibatch processes involving consecutive reactions and based on the topology of a particular phase space, are presented. Such criteria are able to detect both the runaway boundary and the so-called “quick onset, fair conversion, smooth temperature profile” (QFS) operating region by performing a topological analysis of the phase space of the system of ordinary differential equations (ODEs) that describe the analyzed process. Moreover, a safe optimization procedure, the objective of which is to obtain the optimum values both of the dosing time of the dosed reactant and the initial reactor temperature, based on such criteria, has been developed. Finally, such a set of optimum operating parameters has been validated through a comparison with experimental data from published literature.
2010
http://www.scopus.com/record/display.url?eid=2-s2.0-77952346765&origin=resultslist&sort=plf-f&src=s&sid=57037EEB84FBE2C3CC3AF798988493ED.53bsOu7mi7A1NSY7fPJf1g%3a100&sot=aut&sdt=a&sl=37&s=AU-ID%28%22Copelli%2c+Sabrina%22+26221013100%29&relpos=18&relpos=18&citeCnt=8&searchTerm=AU-ID%28%5C%26quot%3BCopelli%2C+Sabrina%5C%26quot%3B+26221013100%29
Copelli, Sabrina; Derudi, M.; Rota, R.
File in questo prodotto:
File Dimensione Formato  
IEC 2010 - RW topologico.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 2.15 MB
Formato Adobe PDF
2.15 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1759577
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 19
social impact