Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of the lead was evaluated in six different body positions. In four patients, no stable position of the atrial electrode could intraoperatively be found. The intraoperative atrial sensing was 2.3 +/- 1.6 mV and the atrial pacing threshold 0.8 +/- 0.5 V at 0.5 ms. At follow-up, the atrial sensing ranged from 1.5 mV to 2.2 mV and the atrial pacing threshold product from 0.8 to 1.7 V/ms. In 11 patients, an intermittent atrial sensing problem and in 24 patients an atrial pacing dysfunction were observed in at least one body position. In 565 episodes, a sensitivity of 100% and a specificity of 96.5% were found for ventricular arrhythmias. In conclusion, this single pass defibrillation lead performed well as a VDD lead and for dual chamber arrhythmia discrimination. However, loss of atrial capture in 45% of patients preclude its use in patients depending on atrial pacing

European clinical experience with a dual chamber single pass sensing and pacing defibrillation lead.2002 Jul;25(7):1079-86.

SALERNO URIARTE, JORGE ANTONIO;
2002-01-01

Abstract

Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of the lead was evaluated in six different body positions. In four patients, no stable position of the atrial electrode could intraoperatively be found. The intraoperative atrial sensing was 2.3 +/- 1.6 mV and the atrial pacing threshold 0.8 +/- 0.5 V at 0.5 ms. At follow-up, the atrial sensing ranged from 1.5 mV to 2.2 mV and the atrial pacing threshold product from 0.8 to 1.7 V/ms. In 11 patients, an intermittent atrial sensing problem and in 24 patients an atrial pacing dysfunction were observed in at least one body position. In 565 episodes, a sensitivity of 100% and a specificity of 96.5% were found for ventricular arrhythmias. In conclusion, this single pass defibrillation lead performed well as a VDD lead and for dual chamber arrhythmia discrimination. However, loss of atrial capture in 45% of patients preclude its use in patients depending on atrial pacing
2002
ICD; pacing
Gradaus, R; Gonska, Bd; Stellbrink, C; Cron, T; Tebbenjohanns, J; Blomström Lundqvist, C; Himmrich, E; SALERNO URIARTE, JORGE ANTONIO; Osswald, S; Gom...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1762017
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact