The SYRMEP (SYnchrotron Radiation for MEdical Physics) collaboration is now developing a microstrip silicon detector with high granularity and high efficiency for research in digital mammography. The project is planning to use a monochromatic X-ray beam, from a bending magnet, of ELETTRA, the synchrotron facility installed in Trieste. The detector is a matrix of pixels, formed by the slacking of different layers of strip silicon pads, with pixel dimensions determined by the pitch and the thickness of the pads themselves. The final detector, an AC-coupled FOXFET-type high resistivity silicon pad, will cover the whole beam region of 4 x 150 mm(2). Different pixel sizes have been tested (from 0.5 x 0.5 mm(2) to 0.3 x 0.2 mm(2)). The dead volume in the front of the detector has been reduced in order to reach 80% efficiency in the photon collection. The stacking of the layers has been obtained by means of screen printing deposits of non-conductive glue whose height has been chosen in order to minimize the inter-layer dead region and the cross talk of superimposed pixels, We present here the results of our studies in terms of imaging and the status of the final detector.

A pixel-like matrix for digital mammography

PREST, MICHELA;
1996-01-01

Abstract

The SYRMEP (SYnchrotron Radiation for MEdical Physics) collaboration is now developing a microstrip silicon detector with high granularity and high efficiency for research in digital mammography. The project is planning to use a monochromatic X-ray beam, from a bending magnet, of ELETTRA, the synchrotron facility installed in Trieste. The detector is a matrix of pixels, formed by the slacking of different layers of strip silicon pads, with pixel dimensions determined by the pitch and the thickness of the pads themselves. The final detector, an AC-coupled FOXFET-type high resistivity silicon pad, will cover the whole beam region of 4 x 150 mm(2). Different pixel sizes have been tested (from 0.5 x 0.5 mm(2) to 0.3 x 0.2 mm(2)). The dead volume in the front of the detector has been reduced in order to reach 80% efficiency in the photon collection. The stacking of the layers has been obtained by means of screen printing deposits of non-conductive glue whose height has been chosen in order to minimize the inter-layer dead region and the cross talk of superimposed pixels, We present here the results of our studies in terms of imaging and the status of the final detector.
1996
SYRMEP; digital mammography; strip detector; synchrotron light
Arfelli, F; Barbiellini, G; Bonvicini, V; Bravin, A; Cantatore, G; Castelli, E; Dimichiel, M; Longo, R; Olivo, A; Pani, S; Pontoni, D; Poropat, P; Pre...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1791088
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact