BACKGROUND: The present study was aimed at determining the impact of type 2 diabetes mellitus (DM) on postoperative bioprosthetic structural valve degeneration. METHODS AND RESULTS: Twelve Italian centers participated in the study. Patient data refer to bioprosthetic implantations performed from November 1988 to December 2009, which resulted in 6184 patients (mean age 71.3±5.4 years, 60.1% male) being enrolled. Of these patients, 1731 (27.9%) had type 2 DM. The propensity score-matching algorithm successfully matched 1113 patients with type 2 DM with the same number of no-DM patients. The postmatching standard differences were less than 0.1 for each of the covariates, and 64.2% of DM patients were matched. The early (30 days) mortality rate was 7.8% (n=87) versus 2.9% (n=33) in patients with or without type 2 DM (P<0.001), respectively. Seven-year freedom from valve deterioration was significantly lower in patients with DM (73.2% [95% confidence interval, 61.6-85.5] versus 95.4% [95% confidence interval, 83.9-100], P<0.001). In Cox regression models with robust SEs that accounted for the clustering of matched pairs, DM was the strongest predictor of structural valve degeneration (hazard ratio 2.39 [95% confidence interval 2.28-3.52]). When we allowed for interaction between type 2 DM and other key risk factors, DM remained a significant predictor beyond any potentially associated variable. CONCLUSIONS: Patients with type 2 DM undergoing bioprosthetic valve implantation are at high risk of early and long-term mortality, as well as of structural valve degeneration.
Type 2 diabetes mellitus is associated with faster degeneration of bioprosthetic valve: results from a propensity score-matched Italian multicenter study.
FERRARESE, SANDRO;SALA, ANDREA ANTONIO;
2012-01-01
Abstract
BACKGROUND: The present study was aimed at determining the impact of type 2 diabetes mellitus (DM) on postoperative bioprosthetic structural valve degeneration. METHODS AND RESULTS: Twelve Italian centers participated in the study. Patient data refer to bioprosthetic implantations performed from November 1988 to December 2009, which resulted in 6184 patients (mean age 71.3±5.4 years, 60.1% male) being enrolled. Of these patients, 1731 (27.9%) had type 2 DM. The propensity score-matching algorithm successfully matched 1113 patients with type 2 DM with the same number of no-DM patients. The postmatching standard differences were less than 0.1 for each of the covariates, and 64.2% of DM patients were matched. The early (30 days) mortality rate was 7.8% (n=87) versus 2.9% (n=33) in patients with or without type 2 DM (P<0.001), respectively. Seven-year freedom from valve deterioration was significantly lower in patients with DM (73.2% [95% confidence interval, 61.6-85.5] versus 95.4% [95% confidence interval, 83.9-100], P<0.001). In Cox regression models with robust SEs that accounted for the clustering of matched pairs, DM was the strongest predictor of structural valve degeneration (hazard ratio 2.39 [95% confidence interval 2.28-3.52]). When we allowed for interaction between type 2 DM and other key risk factors, DM remained a significant predictor beyond any potentially associated variable. CONCLUSIONS: Patients with type 2 DM undergoing bioprosthetic valve implantation are at high risk of early and long-term mortality, as well as of structural valve degeneration.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.