Aims: Catheter ablation of atrial fibrillation (AF) focuses on pulmonary vein (PV) ablation with or without additional atrial substrate modification. These procedures require significant fluoroscopy exposure. A new 3D non-fluoroscopic navigation system (CARTO® 3 System, Biosense Webster, CA, USA) that allows precise location visualization of diagnostic and ablation catheters was evaluated for its impact on fluoroscopic exposure during AF ablation procedures. Methods and Results: Two groups of patients were treated by our centres for drug refractory AF. One group was treated using the new CARTO® 3 system to guide catheter ablation (Group A, 117 patients). The other group was treated using the CARTO® XP system (Biosense Webster) 3 months previously (Group B, 123 patients). For both groups, circumferential PV ostia ablation was performed; PV isolation was validated using a circular catheter placed at each ostium. There was no difference in any clinical characteristics (age, sex, AF type, left atrium diameter and volume, and heart disease) among the two study groups. The mean number of PVs identified and isolated per patient was similar in both groups, as were the mean procedural duration and radiofrequency time. However, mean fluoroscopic time was significantly reduced in Group A (15.9±12.3 min) as compared with Group B (26±15.1 min) (P< 0.001). Conclusion: This multicentre observational study demonstrates a significant reduction of luoroscopy exposure using a new 3D non-fluoroscopic mapping system to guide AF catheter ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2011. For permissions please.

Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system: a multicentre experience.

DE PONTI, ROBERTO;
2012-01-01

Abstract

Aims: Catheter ablation of atrial fibrillation (AF) focuses on pulmonary vein (PV) ablation with or without additional atrial substrate modification. These procedures require significant fluoroscopy exposure. A new 3D non-fluoroscopic navigation system (CARTO® 3 System, Biosense Webster, CA, USA) that allows precise location visualization of diagnostic and ablation catheters was evaluated for its impact on fluoroscopic exposure during AF ablation procedures. Methods and Results: Two groups of patients were treated by our centres for drug refractory AF. One group was treated using the new CARTO® 3 system to guide catheter ablation (Group A, 117 patients). The other group was treated using the CARTO® XP system (Biosense Webster) 3 months previously (Group B, 123 patients). For both groups, circumferential PV ostia ablation was performed; PV isolation was validated using a circular catheter placed at each ostium. There was no difference in any clinical characteristics (age, sex, AF type, left atrium diameter and volume, and heart disease) among the two study groups. The mean number of PVs identified and isolated per patient was similar in both groups, as were the mean procedural duration and radiofrequency time. However, mean fluoroscopic time was significantly reduced in Group A (15.9±12.3 min) as compared with Group B (26±15.1 min) (P< 0.001). Conclusion: This multicentre observational study demonstrates a significant reduction of luoroscopy exposure using a new 3D non-fluoroscopic mapping system to guide AF catheter ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2011. For permissions please.
2012
Ablation; Atrial fibrillation; Radiation exposure;
Stabile, G; Scaglione, M; del Greco, M; DE PONTI, Roberto; Bongiorni, Mg; Zoppo, F; Soldati, E; Marazzi, R; Marini, M; Gaita, F; Iuliano, A; Bertaglia, E.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1898722
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 29
  • Scopus 75
  • ???jsp.display-item.citation.isi??? 60
social impact