Background: Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations (VE) and supplemental O2 flows. Methods: HME efficiency was evaluated using an in vitro lung model at 2 VE (5 and 15 L/min) and 4 supplemental O2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. Results: The progressive increase in O2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower VE. The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8°C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. Conclusions: The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O2 supplementation and VE.

In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients

SEVERGNINI, PAOLO;
2013-01-01

Abstract

Background: Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations (VE) and supplemental O2 flows. Methods: HME efficiency was evaluated using an in vitro lung model at 2 VE (5 and 15 L/min) and 4 supplemental O2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. Results: The progressive increase in O2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower VE. The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8°C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. Conclusions: The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O2 supplementation and VE.
2013
http://www.scopus.com/inward/record.url?eid=2-s2.0-84886299381&partnerID=40&md5=eb596b64e272adffd943ea58fe1564d8
Absolute humidity, Air conditioning, Heat and moisture exchangers, Inspiratory air temperature, Tracheostomized patients
C., Brusasco; F., Corradi; M., Vargas; M., Bona; F., Bruno; M., Marsili; F., Simonassi; G., Santori; Severgnini, Paolo; R., Kacmarek; P., Pelosi
File in questo prodotto:
File Dimensione Formato  
Brusasco Respir Care 2013 in vitro HME tracheo.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 490.98 kB
Formato Adobe PDF
490.98 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/1903122
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 7
social impact