The purpose of this study was to evaluate the influence of a Laser-Lok microtexturing surface on clinical attachment level and crestal bone remodeling around immediately functionally loaded implants in single-tooth replacement. Seventy-seven patients were included in a prospective, randomized study and divided into two groups. Group 1 (control) consisted of non-Laser-Lok type implants (n = 39), while in group 2 (test), Laser-Lok type implants were used (n = 39). Crestal bone loss (CBL) and clinical parameters including clinical attachment level (CAL), Plaque Index (PI), and bleeding on probing were recorded at baseline examinations and at 6, 12, and 24 months after loading with the final restoration. One implant was lost in the control group and one in the test group, giving a total survival rate of 96.1% after 2 years. PI and BOP outcomes were similar for both implant types without statistical differences. A mean CAL loss of 1.10 ± 0.51 mm was observed during the first 2 years in group 1, while the mean CAL loss observed in group 2 was 0.56 ± 0.33 mm. Radiographically, group 1 implants showed a mean crestal bone loss of 1.07 ± 0.30 mm compared with 0.49 ± 0.34 mm for group 2. The type of implant did not influence the survival rate, whereas Laser-Lok implants resulted in greater CAL and in shallower radiographic peri-implant CBL than non-Laser-Lok implants.

Influence of Laser-Lok surface on immediate functional loading of implants in single-tooth replacement: a 2-year prospective clinical study

FARRONATO, DAVIDE;
2014-01-01

Abstract

The purpose of this study was to evaluate the influence of a Laser-Lok microtexturing surface on clinical attachment level and crestal bone remodeling around immediately functionally loaded implants in single-tooth replacement. Seventy-seven patients were included in a prospective, randomized study and divided into two groups. Group 1 (control) consisted of non-Laser-Lok type implants (n = 39), while in group 2 (test), Laser-Lok type implants were used (n = 39). Crestal bone loss (CBL) and clinical parameters including clinical attachment level (CAL), Plaque Index (PI), and bleeding on probing were recorded at baseline examinations and at 6, 12, and 24 months after loading with the final restoration. One implant was lost in the control group and one in the test group, giving a total survival rate of 96.1% after 2 years. PI and BOP outcomes were similar for both implant types without statistical differences. A mean CAL loss of 1.10 ± 0.51 mm was observed during the first 2 years in group 1, while the mean CAL loss observed in group 2 was 0.56 ± 0.33 mm. Radiographically, group 1 implants showed a mean crestal bone loss of 1.07 ± 0.30 mm compared with 0.49 ± 0.34 mm for group 2. The type of implant did not influence the survival rate, whereas Laser-Lok implants resulted in greater CAL and in shallower radiographic peri-implant CBL than non-Laser-Lok implants.
2014
http://www.quintpub.com/journals/prd/full_txt_pdf_alert.php?article_id=13812
Farronato, Davide; Mangano, F.; Briguglio, F.; Iorio Siciliano, V.; Riccitiello, F.; Guarnieri, R.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2022898
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 39
social impact