With an established procedure of molecular imprinting, a synthetic polymer receptor for the neopterin cancer biomarker was devised and used as a recognition unit of a potentiometric chemosensor. For that, bis-bithiophene derivatized with cytosine and bithiophene derivatized with boronic acid were used as functional monomers. The open-circuit potential (OCP) based transduction under flow-injection analysis conditions (FIA) determined neopterin in the concentration range of 0.15-2.5mM with the 22μM limit of detection (LOD) and 7.01(±0.15)mVmM-1 sensitivity indicating its potential suitability in clinical analysis applications. The molecularly imprinted polymer (MIP) film showed an appreciable apparent imprinting factor of ~6. The chemosensor successfully discriminated the interferences including the 6-biopterin and pterin structural analogs of neopterin as well as glucose and creatinine. Moreover, it determined neopterin in synthetic serum samples.

Potentiometric chemosensor for neopterin, a cancer biomarker, using an electrochemically synthesized molecularly imprinted polymer as the recognition unit

BENINCORI, TIZIANA;
2016-01-01

Abstract

With an established procedure of molecular imprinting, a synthetic polymer receptor for the neopterin cancer biomarker was devised and used as a recognition unit of a potentiometric chemosensor. For that, bis-bithiophene derivatized with cytosine and bithiophene derivatized with boronic acid were used as functional monomers. The open-circuit potential (OCP) based transduction under flow-injection analysis conditions (FIA) determined neopterin in the concentration range of 0.15-2.5mM with the 22μM limit of detection (LOD) and 7.01(±0.15)mVmM-1 sensitivity indicating its potential suitability in clinical analysis applications. The molecularly imprinted polymer (MIP) film showed an appreciable apparent imprinting factor of ~6. The chemosensor successfully discriminated the interferences including the 6-biopterin and pterin structural analogs of neopterin as well as glucose and creatinine. Moreover, it determined neopterin in synthetic serum samples.
2016
www.elsevier.com/locate/bios
Cancer biomarker; Molecularly imprinted polymer; Neopterin; Open-circuit potential; Potentiometric chemosensor
Sharma, Piyush Sindhu; Wojnarowicz, Agnieszka; Sosnowska, Marta; Benincori, Tiziana; Noworyta, Krzysztof; D'Souza, Francis; Kutner, Wlodzimierz
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2025024
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 40
social impact