OBJECTIVE: This study investigated the frequency, clinical features, therapeutic options, and results of aortoenteric fistulas (AEFs) developing after endovascular abdominal aortic repair (EVAR). METHODS: Eight Italian centers with an EVAR program participated in this retrospective multicenter study and collected data on AEFs that developed after a previous EVAR. RESULTS: A total of 3932 patients underwent EVAR between 1997 and 2013 at the participating centers. During the same period, 32 patients presented with an AEF during EVAR follow-up, 21 with original EVAR performed for atherosclerotic aneurysmal disease (ATS group) and 11 with the original EVAR performed for a postsurgical pseudoaneurysm (PSA group). The incidence of AEF development after EVAR was 0.46% in the ATS group and 3.9% in the PSA group. Anastomotic PSA as the indication to EVAR (P < .0001) and urgent/emergency EVAR (P = .01) were significantly associated with AEF development. Median time between EVAR and the AEF diagnosis was 32 months (interquartile range, 11-75 months) for the ATS group and 14 months (interquartile range, 10.5-21.5 months) for the PSA group. Among five AEF patients treated conservatively, two (40%) died, at 7 and 15 months, and the remaining three were alive at a median follow-up of 12 months. The AEF was treated surgically in 27 patients, including aortic stent graft explantation in all cases, in situ aortic reconstruction in 14 (52%), and extra-anatomic bypass in 13 (48%). Perioperative mortality was 37% (10 of 27). No additional aortic-related death was recorded in operated-on patients at a median follow-up of 28 months. CONCLUSIONS: Late AEFs rarely occur during EVAR follow-up, but the risk is significantly increased when EVAR is performed for PSA after previous aortic surgery and EVAR is performed as an emergency. Conservative and surgical treatment of post-EVAR AEF are both associated with high mortality. However, beyond the perioperative period, surgical correction of AEFs appears to be durable at midterm follow-up.

Results from the Multicenter Study on Aortoenteric Fistulization After Stent Grafting of the Abdominal Aorta (MAEFISTO).

PIFFARETTI, GABRIELE
Data Curation
;
CASTELLI, PATRIZIO
Membro del Collaboration Group
;
2016-01-01

Abstract

OBJECTIVE: This study investigated the frequency, clinical features, therapeutic options, and results of aortoenteric fistulas (AEFs) developing after endovascular abdominal aortic repair (EVAR). METHODS: Eight Italian centers with an EVAR program participated in this retrospective multicenter study and collected data on AEFs that developed after a previous EVAR. RESULTS: A total of 3932 patients underwent EVAR between 1997 and 2013 at the participating centers. During the same period, 32 patients presented with an AEF during EVAR follow-up, 21 with original EVAR performed for atherosclerotic aneurysmal disease (ATS group) and 11 with the original EVAR performed for a postsurgical pseudoaneurysm (PSA group). The incidence of AEF development after EVAR was 0.46% in the ATS group and 3.9% in the PSA group. Anastomotic PSA as the indication to EVAR (P < .0001) and urgent/emergency EVAR (P = .01) were significantly associated with AEF development. Median time between EVAR and the AEF diagnosis was 32 months (interquartile range, 11-75 months) for the ATS group and 14 months (interquartile range, 10.5-21.5 months) for the PSA group. Among five AEF patients treated conservatively, two (40%) died, at 7 and 15 months, and the remaining three were alive at a median follow-up of 12 months. The AEF was treated surgically in 27 patients, including aortic stent graft explantation in all cases, in situ aortic reconstruction in 14 (52%), and extra-anatomic bypass in 13 (48%). Perioperative mortality was 37% (10 of 27). No additional aortic-related death was recorded in operated-on patients at a median follow-up of 28 months. CONCLUSIONS: Late AEFs rarely occur during EVAR follow-up, but the risk is significantly increased when EVAR is performed for PSA after previous aortic surgery and EVAR is performed as an emergency. Conservative and surgical treatment of post-EVAR AEF are both associated with high mortality. However, beyond the perioperative period, surgical correction of AEFs appears to be durable at midterm follow-up.
2016
Kahlberg, A; Rinaldi, E; Apruzzi, L; Tshomba, Y; Melissano, G; Chiesa, R; Piffaretti, Gabriele; Castelli, Patrizio; Capoccia, L; Sirignano, P; Speziale, F; Segreti, S; Trimarchi, S; Cervi, E; Bonardelli, S; Costantini, E; Baratta, V; Bellosta, R; Sarcina, A.
File in questo prodotto:
File Dimensione Formato  
MAEFISTO.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: DRM non definito
Dimensione 632.11 kB
Formato Adobe PDF
632.11 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2043491
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 41
social impact