Silicon photomultipliers (SiPMs) are an enabling solid-state technology for low light sensing, with single photon sensitivity and photon number resolving capability. They feature an extremely high internal gain at the 106 level, comparable to photomultiplier tubes (PMTs), with the advantage of low operating voltage (~50 V compared to ~1000 V for PMT) and low energy consumption. The solid-state technology makes SiPMs compact, insensitive to magnetic fields and with an extreme flexibility in the design to cope with different applications. The fast development of the multiplication avalanche opens up the possibility to achieve time resolution at the 30 ps level. Dynamic range is however limited compared to PMT and the dark count rate relatively high, yet today at the level of 50 kHz/mm2 at room temperature. Interfaced with scintillation material, SiPMs provide a powerful platform for medical imaging applications (in positron emission tomography/computed tomography and in positron emission tomography/magnetic resonance), for X-ray quality control as well as for novel compact radiation protection instruments. This article gives an overview of SiPMs for medical imaging and dosimetry. In addition, a learning and training program targeted to graduate students is described.

Silicon photomultipliers for medical imaging and dosimetry-an overview

CACCIA, MASSIMO;
2016-01-01

Abstract

Silicon photomultipliers (SiPMs) are an enabling solid-state technology for low light sensing, with single photon sensitivity and photon number resolving capability. They feature an extremely high internal gain at the 106 level, comparable to photomultiplier tubes (PMTs), with the advantage of low operating voltage (~50 V compared to ~1000 V for PMT) and low energy consumption. The solid-state technology makes SiPMs compact, insensitive to magnetic fields and with an extreme flexibility in the design to cope with different applications. The fast development of the multiplication avalanche opens up the possibility to achieve time resolution at the 30 ps level. Dynamic range is however limited compared to PMT and the dark count rate relatively high, yet today at the level of 50 kHz/mm2 at room temperature. Interfaced with scintillation material, SiPMs provide a powerful platform for medical imaging applications (in positron emission tomography/computed tomography and in positron emission tomography/magnetic resonance), for X-ray quality control as well as for novel compact radiation protection instruments. This article gives an overview of SiPMs for medical imaging and dosimetry. In addition, a learning and training program targeted to graduate students is described.
2016
http://rpd.oxfordjournals.org/
Radiology, Nuclear Medicine and Imaging; Radiological and Ultrasound Technology; Radiation; Public Health, Environmental and Occupational Health
Herrnsdorf, L; Caccia, Massimo; Mattsson, S.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2050642
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact