The pilot plant fed by a 600-Nm3 h-1 waste air flow rate consisted of a water scrubbing pre-treatment followed by a biotrickling filter and a biofilter, in series. The growth of selected bacterial and fungal consortia was promoted through the biotrickling filter and biofilter. Total BTEX levels were detected in a raw waste air stream at an average concentration of 39.07 mg Nm-3. The whole treatment achieved an average of 96.1 % removal efficiency. This performance led to very low average concentrations of individual BTEX in the final air effluent: 1.07 mg Nm-3 for benzene, 0.16 mg Nm-3 for toluene, 0.22 mg Nm-3 for ethylbenzene and 0.07 mg Nm-3 for xylene (mix). The performance and stability of both biotrickling filter and biofilter confirmed the effectiveness of the treatment in achieving low concentrations of individual BTEX in the final air effluent, which fully comply with the most stringent toxicological standard and threshold odor concentrations, for the protection of workers and local residents. This result was possible by the complementary and synergistic action of the bacterial and fungal consortia in degrading BTEX.

Treatment of airborne BTEX by a two-stage biotrickling filter and biofilter, exploiting selected bacterial and fungal consortia

TORRETTA, VINCENZO;
2017-01-01

Abstract

The pilot plant fed by a 600-Nm3 h-1 waste air flow rate consisted of a water scrubbing pre-treatment followed by a biotrickling filter and a biofilter, in series. The growth of selected bacterial and fungal consortia was promoted through the biotrickling filter and biofilter. Total BTEX levels were detected in a raw waste air stream at an average concentration of 39.07 mg Nm-3. The whole treatment achieved an average of 96.1 % removal efficiency. This performance led to very low average concentrations of individual BTEX in the final air effluent: 1.07 mg Nm-3 for benzene, 0.16 mg Nm-3 for toluene, 0.22 mg Nm-3 for ethylbenzene and 0.07 mg Nm-3 for xylene (mix). The performance and stability of both biotrickling filter and biofilter confirmed the effectiveness of the treatment in achieving low concentrations of individual BTEX in the final air effluent, which fully comply with the most stringent toxicological standard and threshold odor concentrations, for the protection of workers and local residents. This result was possible by the complementary and synergistic action of the bacterial and fungal consortia in degrading BTEX.
2017
Air pollution; Biofiltration; Biotrickling; BTEX; VOCs
Raboni, Massimo; Torretta, Vincenzo; Viotti, Paolo
File in questo prodotto:
File Dimensione Formato  
95_IJER_BTEX2_Torretta_2017.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 1.34 MB
Formato Adobe PDF
1.34 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2059645
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 19
social impact