Aim: There is little evidence to support choice of technique and configuration for stapled anastomoses after right hemicolectomy and ileocaecal resection. This study aimed to determine the relationship between stapling technique and anastomotic failure. Method: Any unit performing gastrointestinal surgery was invited to contribute data on consecutive adult patients undergoing right hemicolectomy or ileocolic resection to this prospective, observational, international, multicentre study. Patients undergoing stapled, side-to-side ileocolic anastomoses were identified and multilevel, multivariable logistic regression analyses were performed to explore factors associated with anastomotic leak. Results: One thousand three hundred and forty-seven patients were included from 200 centres in 32 countries. The overall anastomotic leak rate was 8.3%. Upon multivariate analysis there was no difference in leak rate with use of a cutting stapler for apical closure compared with a noncutting stapler (8.4% vs 8.0%, OR 0.91, 95% CI 0.54–1.53, P = 0.72). Oversewing of the apical staple line, whether in the cutting group (7.9% vs 9.7%, OR 0.87, 95% CI 0.52–1.46, P = 0.60) or noncutting group (8.9% vs 5.7%, OR 1.40, 95% CI 0.46–4.23, P = 0.55) also conferred no benefit in terms of reducing leak rates. Surgeons reporting to be general surgeons had a significantly higher leak rate than those reporting to be colorectal surgeons (12.1% vs 7.3%, OR 1.65, 95% CI 1.04–2.64, P = 0.04). Conclusion: This study did not identify any difference in anastomotic leak rates according to the type of stapling device used to close the apical aspect. In addition, oversewing of the anastomotic staple lines appears to confer no benefit in terms of reducing leak rates. Although general surgeons operated on patients with more high-risk characteristics than colorectal surgeons, a higher leak rate for general surgeons which remained after risk adjustment needs further exploration.
The impact of stapling technique and surgeon specialism on anastomotic failure after right-sided colorectal resection: an international multicentre, prospective audit
Aim: There is little evidence to support choice of technique and configuration for stapled anastomoses after right hemicolectomy and ileocaecal resection. This study aimed to determine the relationship between stapling technique and anastomotic failure. Method: Any unit performing gastrointestinal surgery was invited to contribute data on consecutive adult patients undergoing right hemicolectomy or ileocolic resection to this prospective, observational, international, multicentre study. Patients undergoing stapled, side-to-side ileocolic anastomoses were identified and multilevel, multivariable logistic regression analyses were performed to explore factors associated with anastomotic leak. Results: One thousand three hundred and forty-seven patients were included from 200 centres in 32 countries. The overall anastomotic leak rate was 8.3%. Upon multivariate analysis there was no difference in leak rate with use of a cutting stapler for apical closure compared with a noncutting stapler (8.4% vs 8.0%, OR 0.91, 95% CI 0.54–1.53, P = 0.72). Oversewing of the apical staple line, whether in the cutting group (7.9% vs 9.7%, OR 0.87, 95% CI 0.52–1.46, P = 0.60) or noncutting group (8.9% vs 5.7%, OR 1.40, 95% CI 0.46–4.23, P = 0.55) also conferred no benefit in terms of reducing leak rates. Surgeons reporting to be general surgeons had a significantly higher leak rate than those reporting to be colorectal surgeons (12.1% vs 7.3%, OR 1.65, 95% CI 1.04–2.64, P = 0.04). Conclusion: This study did not identify any difference in anastomotic leak rates according to the type of stapling device used to close the apical aspect. In addition, oversewing of the anastomotic staple lines appears to confer no benefit in terms of reducing leak rates. Although general surgeons operated on patients with more high-risk characteristics than colorectal surgeons, a higher leak rate for general surgeons which remained after risk adjustment needs further exploration.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2076976
Attenzione
L'Ateneo sottopone a validazione solo i file PDF allegati
Citazioni
14
34
31
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.