Purpose: PEAK PlasmaBlade is a recent and distinctive type of electrosurgical device. Previous studies have already documented some meaningful advantages of this device over conventional electrosurgery. This study compared the use of PEAK PlasmaBlade to standard electrosurgery in mastectomy and breast conservative surgery. The purpose was to test the impact of PEAK PlasmaBlade on the wound-healing process and on postsurgical complications in breast cancer surgery. Methods: Sixty patients undergoing breast cancer surgery were enrolled. The PEAK PlasmaBlade was used for 20 of those. A standard electrosurgical device was used for the other 40 patients. The 2 groups were homogenous in age, body mass index, comorbidities and type of surgery. We recorded wound complications, serum drainage amount and duration of stay, blood loss, time of surgery, length of hospital stay, and total number of medications required. Results: The 2 groups were not significantly different in terms of patient characteristics. A statistically significant reduction in incidence of seroma was observed in the PEAK group: only 10% versus 37.5% of the patients in the conventional electrosurgery group developed this complication (Fisher exact test, P = 0.034). Conclusion: Seroma is the most important wound complication in breast surgery. The research of new instruments that might reduce its incidence is desirable. In order to validate or deny the results of this study, it is necessary to enroll more subjects and to consider the impact of this device on axillary lymph node dissection.

Wound healing and postsurgical complications in breast cancer surgery: A comparison between PEAK PlasmaBlade and conventional electrosurgery – A preliminary report of a case series

Dionigi, Gianlorenzo;Rovera, Francesca
2018-01-01

Abstract

Purpose: PEAK PlasmaBlade is a recent and distinctive type of electrosurgical device. Previous studies have already documented some meaningful advantages of this device over conventional electrosurgery. This study compared the use of PEAK PlasmaBlade to standard electrosurgery in mastectomy and breast conservative surgery. The purpose was to test the impact of PEAK PlasmaBlade on the wound-healing process and on postsurgical complications in breast cancer surgery. Methods: Sixty patients undergoing breast cancer surgery were enrolled. The PEAK PlasmaBlade was used for 20 of those. A standard electrosurgical device was used for the other 40 patients. The 2 groups were homogenous in age, body mass index, comorbidities and type of surgery. We recorded wound complications, serum drainage amount and duration of stay, blood loss, time of surgery, length of hospital stay, and total number of medications required. Results: The 2 groups were not significantly different in terms of patient characteristics. A statistically significant reduction in incidence of seroma was observed in the PEAK group: only 10% versus 37.5% of the patients in the conventional electrosurgery group developed this complication (Fisher exact test, P = 0.034). Conclusion: Seroma is the most important wound complication in breast surgery. The research of new instruments that might reduce its incidence is desirable. In order to validate or deny the results of this study, it is necessary to enroll more subjects and to consider the impact of this device on axillary lymph node dissection.
2018
https://thesurgery.or.kr/Synapse/Data/PDFData/6037ASTR/astr-95-129.pdf
Breast neoplasms; Equipment; Intraoperative complications; Operative surgical procedures; Supplies; Wound infection; Surgery
Chiappa, Corrado; Fachinetti, Anna; Boeri, Carlo; Arlant, Veronica; Rausei, Stefano; Dionigi, Gianlorenzo; Rovera, Francesca
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2077833
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact