Silicon Photomultipliers with cell-pitch ranging from 12 μm to 20 μm were tested against neutron irradiation at moderate fluences to study their performance for calorimetric applications. The photosensors were developed by FBK employing the RGB-HD technology. We performed irradiation tests up to 2 × 1011 n/cm2 (1 MeV eq.) at the INFN-LNL Irradiation Test facility. The SiPMs were characterized on-site (dark current and photoelectron response) during and after irradiations at different fluences. The irradiated SiPMs were installed in the ENUBET compact calorimetric modules and characterized with muons and electrons at the CERN East Area facility. The tests demonstrate that both the electromagnetic response and the sensitivity to minimum ionizing particles are retained after irradiation. Gain compensation can be achieved increasing the bias voltage well within the operation range of the SiPMs. The sensitivity to single photoelectrons is lost at ∼ 1010 n/cm2 due to the increase of the dark current.

Irradiation and performance of RGB-HD Silicon Photomultipliers for calorimetric applications

Ballerini, G.;Berra, A.;Brizzolari, C.;Mascagna, V.;Prest, M.;Soldani, M.;
2019-01-01

Abstract

Silicon Photomultipliers with cell-pitch ranging from 12 μm to 20 μm were tested against neutron irradiation at moderate fluences to study their performance for calorimetric applications. The photosensors were developed by FBK employing the RGB-HD technology. We performed irradiation tests up to 2 × 1011 n/cm2 (1 MeV eq.) at the INFN-LNL Irradiation Test facility. The SiPMs were characterized on-site (dark current and photoelectron response) during and after irradiations at different fluences. The irradiated SiPMs were installed in the ENUBET compact calorimetric modules and characterized with muons and electrons at the CERN East Area facility. The tests demonstrate that both the electromagnetic response and the sensitivity to minimum ionizing particles are retained after irradiation. Gain compensation can be achieved increasing the bias voltage well within the operation range of the SiPMs. The sensitivity to single photoelectrons is lost at ∼ 1010 n/cm2 due to the increase of the dark current.
2019
https://iopscience.iop.org/article/10.1088/1748-0221/14/02/P02029/pdf
Calorimeters; Neutrino detectors; Photon detectors for UV, visible and IR photons (solid-state); Radiation damage to detector materials (solid state);
Acerbi, F.; Ballerini, G.; Berra, A.; Brizzolari, C.; Brunetti, G.; Catanesi, M. G.; Cecchini, S.; Cindolo, F.; Coffani, A.; Collazuol, G.; Conti, E.;...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2077910
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 14
social impact