Objective: The objective of this study was to compare the efficacy of renal perfusion with Custodiol (Dr Franz-Kohler Chemie GmbH, Bensheim, Germany) versus enriched Ringer's solution for renal protection in patients undergoing open thoracoabdominal aortic aneurysm (TAAA) repair. Methods: Ninety consecutive patients scheduled for elective open TAAA repair were enrolled between 2015 and 2017 in a single-center, phase IV, prospective, parallel, randomized, double-blind trial (the CUstodiol versus RInger: whaT Is the Best Agent [CURITIBA] trial), and randomized to renal arteries perfusion with 4°C Custodiol (Dr Franz-Kohler Chemie GmbH, Bensheim, Germany; n = 45) or 4°C lactated Ringer's solution (n = 45). The incidence of acute kidney injury (AKI) in patients undergoing TAAA open surgery using Custodiol renal perfusion versus an enriched Ringer's solution was the primary end point. Results: Ninety patients completed the study (45 patients in each group). The incidence of postoperative AKI was significantly lower in the Custodiol group (48.9% vs 75.6%; P = .02). In the multivariable model, only the use of Custodiol solution resulted as protective from the occurrence of any AKI (odds ratio, 0.230; 95% confidence interval, 0.086-0.614; P = .003), whereas TAAA type II extent was associated with the development of severe AKI (odds ratio, 4.277; 95% confidence interval, 1.239-14.762; P = .02). At 1-year follow-up, serum creatinine was not significantly different from the preoperative values in both groups. Conclusions: The use of Custodiol during open TAAA repair was safe and resulted in significantly lower rates of postoperative AKI compared with Ringer's solution. These findings support safety and efficacy of Custodiol in this specific setting, which is currently off-label.

Renal perfusion with histidine-tryptophan-ketoglutarate compared with Ringer's solution in patients undergoing thoracoabdominal aortic open repair

Venturini M.
2023-01-01

Abstract

Objective: The objective of this study was to compare the efficacy of renal perfusion with Custodiol (Dr Franz-Kohler Chemie GmbH, Bensheim, Germany) versus enriched Ringer's solution for renal protection in patients undergoing open thoracoabdominal aortic aneurysm (TAAA) repair. Methods: Ninety consecutive patients scheduled for elective open TAAA repair were enrolled between 2015 and 2017 in a single-center, phase IV, prospective, parallel, randomized, double-blind trial (the CUstodiol versus RInger: whaT Is the Best Agent [CURITIBA] trial), and randomized to renal arteries perfusion with 4°C Custodiol (Dr Franz-Kohler Chemie GmbH, Bensheim, Germany; n = 45) or 4°C lactated Ringer's solution (n = 45). The incidence of acute kidney injury (AKI) in patients undergoing TAAA open surgery using Custodiol renal perfusion versus an enriched Ringer's solution was the primary end point. Results: Ninety patients completed the study (45 patients in each group). The incidence of postoperative AKI was significantly lower in the Custodiol group (48.9% vs 75.6%; P = .02). In the multivariable model, only the use of Custodiol solution resulted as protective from the occurrence of any AKI (odds ratio, 0.230; 95% confidence interval, 0.086-0.614; P = .003), whereas TAAA type II extent was associated with the development of severe AKI (odds ratio, 4.277; 95% confidence interval, 1.239-14.762; P = .02). At 1-year follow-up, serum creatinine was not significantly different from the preoperative values in both groups. Conclusions: The use of Custodiol during open TAAA repair was safe and resulted in significantly lower rates of postoperative AKI compared with Ringer's solution. These findings support safety and efficacy of Custodiol in this specific setting, which is currently off-label.
2023
2021
acute kidney injury; chronic kidney disease stage; Custodiol solution; enriched Ringer's; thoracoabdominal aortic aneurysm
Kahlberg, A.; Tshomba, Y.; Baccellieri, D.; Bertoglio, L.; Rinaldi, E.; Ardita, V.; Colombo, E.; Moscato, U.; Melissano, G.; Chiesa, R.; Apruzzi, L.; ...espandi
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0022522321004086-main.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 3.56 MB
Formato Adobe PDF
3.56 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2114073
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 24
social impact