Background: The magnetic sphincter augmentation (MSA) device has become a common option for the treatment of gastroesophageal reflux disease (GERD). Knowledge of MSA-related complications, indications for removal, and techniques are puzzled. With this study, we aimed to evaluate indications, techniques for removal, surgical approach, and outcomes with MSA removal. Methods: This is an observational singe-center study. Patients were followed up regularly with endoscopy, pH monitoring, and assessed for specific gastroesophageal reflux disease health-related quality of life (GERD-HRQL) and generic short-form 36 (SF-36) quality of life. Results: Five patients underwent MSA explant. Four patients were males and the median age was 47 years (range 44–55). Heartburn, epigastric/chest pain, and dysphagia were commonly reported. The median implant duration was 46 months (range 31–72). A laparoscopic approach was adopted in all patients. Intraoperative findings included normal anatomy (40%), herniation in the mediastinum (40%), and erosion (20%). The most common anti-reflux procedures were Dor (n = 2), Toupet (n = 2), and anterior partial fundoplication (n = 1). The median operative time was 145 min (range 60–185), and the median hospital length of stay was 4 days (range 3–6). The median postoperative follow-up was 41 months (range 12–51). At the last follow-up, 80% of patients were off PPI; the GERD-HRQL and SF-36 questionnaire were improved with DeMeester score and esophageal acid exposure normalization. Conclusion: The MSA device can be safely explanted through a single-stage laparoscopic procedure. Tailoring a fundoplication, according to preoperative patient symptoms and intraoperative findings, seems feasible and safe with a promising trend toward improved symptoms and quality of life.

Magnetic sphincter augmentation device removal: surgical technique and results at medium-term follow-up

Cavalli M.;Campanelli G.;
2021-01-01

Abstract

Background: The magnetic sphincter augmentation (MSA) device has become a common option for the treatment of gastroesophageal reflux disease (GERD). Knowledge of MSA-related complications, indications for removal, and techniques are puzzled. With this study, we aimed to evaluate indications, techniques for removal, surgical approach, and outcomes with MSA removal. Methods: This is an observational singe-center study. Patients were followed up regularly with endoscopy, pH monitoring, and assessed for specific gastroesophageal reflux disease health-related quality of life (GERD-HRQL) and generic short-form 36 (SF-36) quality of life. Results: Five patients underwent MSA explant. Four patients were males and the median age was 47 years (range 44–55). Heartburn, epigastric/chest pain, and dysphagia were commonly reported. The median implant duration was 46 months (range 31–72). A laparoscopic approach was adopted in all patients. Intraoperative findings included normal anatomy (40%), herniation in the mediastinum (40%), and erosion (20%). The most common anti-reflux procedures were Dor (n = 2), Toupet (n = 2), and anterior partial fundoplication (n = 1). The median operative time was 145 min (range 60–185), and the median hospital length of stay was 4 days (range 3–6). The median postoperative follow-up was 41 months (range 12–51). At the last follow-up, 80% of patients were off PPI; the GERD-HRQL and SF-36 questionnaire were improved with DeMeester score and esophageal acid exposure normalization. Conclusion: The MSA device can be safely explanted through a single-stage laparoscopic procedure. Tailoring a fundoplication, according to preoperative patient symptoms and intraoperative findings, seems feasible and safe with a promising trend toward improved symptoms and quality of life.
2021
Dysphagia; Gastroesophageal reflux disease (GERD); Magnetic sphincter augmentation device; Removal
Bona, D.; Saino, G.; Mini, E.; Lombardo, F.; Panizzo, V.; Cavalli, M.; Bonitta, G.; Campanelli, G.; Aiolfi, A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2115425
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact