The choice of the motor donor nerve is a crucial point in free flap transfer algorithms. In the case of unilateral facial paralysis, the contralateral healthy facial nerve can provide coordinated smile animation and spontaneous emotional expression, but with unpredictable axonal ingrowth into the recipient muscle. Otherwise, the masseteric nerve ipsilateral to the paralysis can provide a powerful neural input, without a spontaneous trigger of the smile. Harvesting a bulky muscular free flap may enhance the quantity of contraction but esthetic results are unpleasant. Therefore, the logical solution for obtaining high amplitude of smiling combined with spontaneity of movement is to couple the neural input: the contralateral facial nerve plus the ipsilateral masseteric nerve. Thirteen patients with unilateral dense facial paralysis underwent a one-stage facial reanimation with a gracilis flap powered by a double donor neural input, provided by both the ipsilateral masseteric nerve (coaptation by an end-to-end neurorrhaphy with the obturator nerve) and the contralateral facial nerve (coaptation through a cross-face nerve graft: end-to-end neurorrhaphy on the healthy side and end-to-side neurorrhaphy on the obturator nerve, distal to the masseteric/obturator neurorrhaphy). Their facial movements were evaluated with an optoelectronic motion analyzer. Before surgery, on average, the paretic side exhibited a smaller total three-dimensional mobility than the healthy side, with a 52% activation ratio and >30% of asymmetry. After surgery, the differences significantly decreased (analysis of variance (ANOVA), p < 0.05), with an activation ratio between 75% (maximum smile) and 91% (maximum smile with teeth clenching), and <20% of asymmetry. Similar modifications were seen for the performance of spontaneous smiles. The significant presurgical asymmetry of labial movements reduced after surgery. The use of a double donor neural input permitted both movements that were similar in force to that of the healthy side, and spontaneous movements elicited by emotional triggering.
Double-powered free gracilis muscle transfer for smile reanimation: A longitudinal optoelectronic study
Rabbiosi D;
2015-01-01
Abstract
The choice of the motor donor nerve is a crucial point in free flap transfer algorithms. In the case of unilateral facial paralysis, the contralateral healthy facial nerve can provide coordinated smile animation and spontaneous emotional expression, but with unpredictable axonal ingrowth into the recipient muscle. Otherwise, the masseteric nerve ipsilateral to the paralysis can provide a powerful neural input, without a spontaneous trigger of the smile. Harvesting a bulky muscular free flap may enhance the quantity of contraction but esthetic results are unpleasant. Therefore, the logical solution for obtaining high amplitude of smiling combined with spontaneity of movement is to couple the neural input: the contralateral facial nerve plus the ipsilateral masseteric nerve. Thirteen patients with unilateral dense facial paralysis underwent a one-stage facial reanimation with a gracilis flap powered by a double donor neural input, provided by both the ipsilateral masseteric nerve (coaptation by an end-to-end neurorrhaphy with the obturator nerve) and the contralateral facial nerve (coaptation through a cross-face nerve graft: end-to-end neurorrhaphy on the healthy side and end-to-side neurorrhaphy on the obturator nerve, distal to the masseteric/obturator neurorrhaphy). Their facial movements were evaluated with an optoelectronic motion analyzer. Before surgery, on average, the paretic side exhibited a smaller total three-dimensional mobility than the healthy side, with a 52% activation ratio and >30% of asymmetry. After surgery, the differences significantly decreased (analysis of variance (ANOVA), p < 0.05), with an activation ratio between 75% (maximum smile) and 91% (maximum smile with teeth clenching), and <20% of asymmetry. Similar modifications were seen for the performance of spontaneous smiles. The significant presurgical asymmetry of labial movements reduced after surgery. The use of a double donor neural input permitted both movements that were similar in force to that of the healthy side, and spontaneous movements elicited by emotional triggering.File | Dimensione | Formato | |
---|---|---|---|
Double-powered free gracilis muscle transfer for smile reanimation: A longitudinal optoelectronic study .pdf
non disponibili
Tipologia:
Versione Editoriale (PDF)
Licenza:
DRM non definito
Dimensione
2.1 MB
Formato
Adobe PDF
|
2.1 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.