(1) Objectives: In patients with symptoms suggestive of rectosigmoid endometriosis, imaging techniques are required to confirm the presence and establish the extent of the disease. The objective of the current study was to compare the performance of three-dimensional rectal water contrast transvaginal ultrasonography (3D-RWC-TVS) and computed tomographic colonography (CTC) in predicting the presence and characteristics of rectosigmoid endometriosis. (2) Methods: This prospective study included patients with suspicion of rectosigmoid endometriosis who underwent both 3D-RWC-TVS and CTC and subsequently were surgically treated. The findings of imaging techniques were compared with surgical and histological results. (3) Results: Out of 68 women included in the study, 37 (48.9; 95% C.I. 38.2-59.7%) had rectosigmoid nodules and underwent bowel surgery. There was no significant difference in the accuracy of 3D-RWC-TVS and CTC in diagnosing the presence of rectosigmoid endometriotic nodules (p = 0.118), although CTC was more precise in diagnosing endometriosis located in the sigmoid (p = 0.016). 3D-RWC-TVS and CTC had similar precision in estimating the largest diameter of the main endometriotic nodule (p = 0.099) and, in patients undergoing segmental resection, the degree of the stenosis of the bowel lumen (p = 0.293). CTC was more accurate in estimating the distance between the lower margin of the intestinal nodule and the anal verge (p = 0.030) but was less tolerated than 3D-RWC-TVS (p < 0.001). (4) Conclusion: This was the first study comparing the performance of 3D-RWC-TVS and CTC in the diagnosis of rectosigmoid endometriosis. Both techniques allowed for the evaluation of the profile of the bowel lumen in a pseudoendoscopic fashion and had a similar performance for the diagnosis of rectosigmoid endometriosis, although CTC was more accurate in diagnosing and characterizing sigmoid nodules.

A prospective study comparing three-dimensional rectal water contrast transvaginal ultrasonography and computed tomographic colonography in the diagnosis of rectosigmoid endometriosis

Ghezzi F.;
2020-01-01

Abstract

(1) Objectives: In patients with symptoms suggestive of rectosigmoid endometriosis, imaging techniques are required to confirm the presence and establish the extent of the disease. The objective of the current study was to compare the performance of three-dimensional rectal water contrast transvaginal ultrasonography (3D-RWC-TVS) and computed tomographic colonography (CTC) in predicting the presence and characteristics of rectosigmoid endometriosis. (2) Methods: This prospective study included patients with suspicion of rectosigmoid endometriosis who underwent both 3D-RWC-TVS and CTC and subsequently were surgically treated. The findings of imaging techniques were compared with surgical and histological results. (3) Results: Out of 68 women included in the study, 37 (48.9; 95% C.I. 38.2-59.7%) had rectosigmoid nodules and underwent bowel surgery. There was no significant difference in the accuracy of 3D-RWC-TVS and CTC in diagnosing the presence of rectosigmoid endometriotic nodules (p = 0.118), although CTC was more precise in diagnosing endometriosis located in the sigmoid (p = 0.016). 3D-RWC-TVS and CTC had similar precision in estimating the largest diameter of the main endometriotic nodule (p = 0.099) and, in patients undergoing segmental resection, the degree of the stenosis of the bowel lumen (p = 0.293). CTC was more accurate in estimating the distance between the lower margin of the intestinal nodule and the anal verge (p = 0.030) but was less tolerated than 3D-RWC-TVS (p < 0.001). (4) Conclusion: This was the first study comparing the performance of 3D-RWC-TVS and CTC in the diagnosis of rectosigmoid endometriosis. Both techniques allowed for the evaluation of the profile of the bowel lumen in a pseudoendoscopic fashion and had a similar performance for the diagnosis of rectosigmoid endometriosis, although CTC was more accurate in diagnosing and characterizing sigmoid nodules.
2020
Bowel endometriosis; Bowel stenosis; Computed colonography; Intestinal segmental resection; Rectosigmoid endometriosis; Three-dimensional rectal water contrast transvaginal ultrasonography
Barra, F.; Biscaldi, E.; Scala, C.; Laganà, A. S.; Vellone, V. G.; Stabilini, C.; Ghezzi, F.; Ferrero, S.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2120356
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 20
social impact