An innovative precast shear wall with inner lightening profiles and mechanical connections has been recently proposed as an evo-lution of the standard large panel technology for residential precast systems. The structural behaviour of the proposed wall system under flexure has been previously assessed, including seismic testing of a full-scale multi-storey building. This paper presents the results of lateral shear tests carried out at the LPMSC laboratory of Politecnico di Milano on four precast bearing wall panel ele-ments of this system, aimed at characterising its structural behaviour under shear and the influence of different shear reinforce-ment layouts. Different shear failure modes have been identified, from diagonal tension-shear in weakly-reinforced walls to hori-zontal sliding-shear in heavily-reinforced walls. A strut and tie model was also set up to give the experimental results an enginee-ring interpretation.

Un innovativo elemento di muro portante prefabbricato con elementi di alleggerimento interni e connessioni meccaniche è stato recentemente proposto come un’evoluzione dei sistemi tradizionali a grandi pannelli impiegati per la costruzione di edifici resi-denziali. Il comportamento flessionale del muro proposto è stato oggetto di precedenti attività di ricerca che hanno incluso prove sismiche su un edificio multipiano in scala al vero. L’articolo presenta i risultati di prove di taglio laterale cicliche svolte presso il laboratorio LPMSC del Politecnico di Milano su quattro elementi di muro rivolte alla caratterizzazione del comportamento meccanico del muro a taglio con l’impiego di differenti schemi di disposizione di armatura di parete. Sono stati identificati diver-si modi di rottura a taglio, da taglio-trazione diagonale in muri debolmente armati a taglio-scorrimento orizzontale in muri mag-giormente armati. Un modello puntoni e tiranti è stato inoltre impiegato per fornire un’interpretazione ingegneristica ai risultati sperimentali.

Lateral shear cyclic testing of full-scale precast bearing wall panels with inner lightening profiles and mechanical connections / prove cicliche a taglio laterale di elementi di muro prefabbricati con profili di alleggerimento e connessioni meccaniche

Bruno Dal Lago
;
2021-01-01

Abstract

An innovative precast shear wall with inner lightening profiles and mechanical connections has been recently proposed as an evo-lution of the standard large panel technology for residential precast systems. The structural behaviour of the proposed wall system under flexure has been previously assessed, including seismic testing of a full-scale multi-storey building. This paper presents the results of lateral shear tests carried out at the LPMSC laboratory of Politecnico di Milano on four precast bearing wall panel ele-ments of this system, aimed at characterising its structural behaviour under shear and the influence of different shear reinforce-ment layouts. Different shear failure modes have been identified, from diagonal tension-shear in weakly-reinforced walls to hori-zontal sliding-shear in heavily-reinforced walls. A strut and tie model was also set up to give the experimental results an enginee-ring interpretation.
2021
Italian Concrete Days 2020
Italian Concrete Days 2020
Napoli, Italia
10-12 giugno 2021
Un innovativo elemento di muro portante prefabbricato con elementi di alleggerimento interni e connessioni meccaniche è stato recentemente proposto come un’evoluzione dei sistemi tradizionali a grandi pannelli impiegati per la costruzione di edifici resi-denziali. Il comportamento flessionale del muro proposto è stato oggetto di precedenti attività di ricerca che hanno incluso prove sismiche su un edificio multipiano in scala al vero. L’articolo presenta i risultati di prove di taglio laterale cicliche svolte presso il laboratorio LPMSC del Politecnico di Milano su quattro elementi di muro rivolte alla caratterizzazione del comportamento meccanico del muro a taglio con l’impiego di differenti schemi di disposizione di armatura di parete. Sono stati identificati diver-si modi di rottura a taglio, da taglio-trazione diagonale in muri debolmente armati a taglio-scorrimento orizzontale in muri mag-giormente armati. Un modello puntoni e tiranti è stato inoltre impiegato per fornire un’interpretazione ingegneristica ai risultati sperimentali.
File in questo prodotto:
File Dimensione Formato  
icd2020_Dal_Lago_Del_Galdo_Dal_Lago_Vazzaza_Ferrara_rev.pdf

non disponibili

Descrizione: full paper
Tipologia: Versione Editoriale (PDF)
Licenza: DRM non definito
Dimensione 1.73 MB
Formato Adobe PDF
1.73 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2123590
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact