New precast frame industrial structures are seismically designed according to reliable modern criteria. However, most of the existing built stock hosting many workers and both regular and strategic industrial activities was designed and detailed neglecting the earthquake load or according to outdated seismic design criteria and regulations. Its seismic retrofit is a main challenge for the Engineering Community and a critical objective for institutional and private bodies. Among the envisaged solutions, the introduction of dissipative braces appears to be promising, although mostly inapplicable for these buildings, due to the brace lengths required by their typical large dimensions and the related proportioning against buckling. In this paper, an innovative seismic retrofitting technique based on monolateral dissipative bracing is investigated. The device proposed in this paper, yet in phase of preliminary design and testing, dissipates energy through friction in tension only while freely deforming in compression, which makes the issue related to compressive buckling irrelevant. A numerical analysis is carried out to investigate the efficiency of the proposed device in seismic retrofitting of precast industrial frame buildings with the aim to explore its feasibility and to better orient the definition of the slip threshold load range and the future development of the physical device. The simplified Capacity Spectrum Method (CSM) is employed for the global framing of the structural behaviour of the highly nonlinear retrofitted structures under seismic actions. A numerical tool is set to automatically apply the CSM based on the definition of few main parameters governing the seismic response of precast frame structures. The efficacy of the CSM is critically analysed through the comparison with the results of a set of nonlinear dynamic analyses. A smart simplified design process aimed at framing the most efficient threshold slip/yield load of the device given an existing structural configuration is presented with the application of the CSM through the identification of the most efficient performance indicator related to either displacement, shear force, equivalent dissipation of energy or a combination of them.

Tension-only ideal dissipative bracing for the seismic retrofit of precast industrial buildings

Dal Lago B.
;
2021-01-01

Abstract

New precast frame industrial structures are seismically designed according to reliable modern criteria. However, most of the existing built stock hosting many workers and both regular and strategic industrial activities was designed and detailed neglecting the earthquake load or according to outdated seismic design criteria and regulations. Its seismic retrofit is a main challenge for the Engineering Community and a critical objective for institutional and private bodies. Among the envisaged solutions, the introduction of dissipative braces appears to be promising, although mostly inapplicable for these buildings, due to the brace lengths required by their typical large dimensions and the related proportioning against buckling. In this paper, an innovative seismic retrofitting technique based on monolateral dissipative bracing is investigated. The device proposed in this paper, yet in phase of preliminary design and testing, dissipates energy through friction in tension only while freely deforming in compression, which makes the issue related to compressive buckling irrelevant. A numerical analysis is carried out to investigate the efficiency of the proposed device in seismic retrofitting of precast industrial frame buildings with the aim to explore its feasibility and to better orient the definition of the slip threshold load range and the future development of the physical device. The simplified Capacity Spectrum Method (CSM) is employed for the global framing of the structural behaviour of the highly nonlinear retrofitted structures under seismic actions. A numerical tool is set to automatically apply the CSM based on the definition of few main parameters governing the seismic response of precast frame structures. The efficacy of the CSM is critically analysed through the comparison with the results of a set of nonlinear dynamic analyses. A smart simplified design process aimed at framing the most efficient threshold slip/yield load of the device given an existing structural configuration is presented with the application of the CSM through the identification of the most efficient performance indicator related to either displacement, shear force, equivalent dissipation of energy or a combination of them.
2021
2021
Bracing system; Capacity spectrum; Dissipative devices; Industrial buildings; Precast structures; Seismic retrofit
Dal Lago, B.; Naveed, M.; Lamperti Tornaghi, M.
File in questo prodotto:
File Dimensione Formato  
s10518-021-01130-z.pdf

accesso aperto

Descrizione: full paper
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 3.94 MB
Formato Adobe PDF
3.94 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2123600
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 9
social impact