Few researches on domestic indoor air pollution have given quantitative information on the variation of the characteristics of the indoor source of particulate matter (PM). This paper is intended to contribute to the understanding of this phenomenon referring to beef-steak cooking by means of natural gas, that is expected to be a cleaner source of PM, especially compared with biomass. The originality of this paper is based on the variability of the power of the cooker in order to study the sustainability of natural gas from the point of view of the induced indoor human exposure to PM. Measurements were made by a GRIMM analyzer, able to measures 16 granulometric classes from 0.3 to 20 µm. Using the biggest cooker, the PM10 production resulted 3 times higher than the case with the smaller one, even if the appearance of the cooked steaks was the same. In particular, this increase is higher for the finest fractions of PM. It is clear that a good ventilation is compulsory to reduce the human exposure to this kind of source.

Indoor measurements of particulate matter during beef-steak cooking under different conditions

Schiavon, Marco;Rada, Elena Cristina;Ragazzi, Marco;
2013-01-01

Abstract

Few researches on domestic indoor air pollution have given quantitative information on the variation of the characteristics of the indoor source of particulate matter (PM). This paper is intended to contribute to the understanding of this phenomenon referring to beef-steak cooking by means of natural gas, that is expected to be a cleaner source of PM, especially compared with biomass. The originality of this paper is based on the variability of the power of the cooker in order to study the sustainability of natural gas from the point of view of the induced indoor human exposure to PM. Measurements were made by a GRIMM analyzer, able to measures 16 granulometric classes from 0.3 to 20 µm. Using the biggest cooker, the PM10 production resulted 3 times higher than the case with the smaller one, even if the appearance of the cooked steaks was the same. In particular, this increase is higher for the finest fractions of PM. It is clear that a good ventilation is compulsory to reduce the human exposure to this kind of source.
2013
Energy and sustainability IV
9781845647285
ESUS13
Bucharest
19-21 June 2013
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2127196
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? ND
social impact