Study objective: Viscoelastic point-of-care (POC) tests are commonly used to provide prompt diagnosis of coagulopathy and allow targeted treatments in bleeding patients on ECMO. We evaluated the clinical effectiveness of point-of-care (POC) testing for anticoagulation management in patients on extracorporeal membrane oxygenation (ECMO). Design: Systematic review and meta-analysis. Eligible studies evaluating the use of thromboelastography- or thromboelastometry-guided algorithms, anti-factor Xa and platelet function testing were selected after screening the literature from July 1975 to January 2020. Setting: Patients on ECMO support. Patients: Anticoagulation management on ECMO patients. Interventions: Rotational thromboelastometry, thromboelastography, alone or combined with platelet function testing. Trials monitoring the anticoagulation effects during ECMO using an anti-factor Xa assay were included in the systematic review. Measurements: The primary outcomes were bleeding events, surgical revisions, thrombosis events and ECMO circuit change/failure. Secondary outcomes were blood-product transfusions, cerebrovascular accidents, mortality on ECMO, ECMO duration, intensive care unit and hospital discharge rates, and in-hospital mortality. Main results: Thirty-one trials enrolling 1684 participants were included in the systematic review. Four trials enrolling 547 subjects were included in the meta-analysis. The use of a POC testing device resulted in improved detection of surgical bleeding (RR: 0.68, 95% CI 0.49 to 0.94, I2 = 0%; χ2 test for heterogeneity, P = 0.02). The use of POC-guided algorithms did not affect bleeding (RR:0.78, 95% CI 0.58 to 1.04, I2 = 47%; χ2 test for heterogeneity, P = 0.09), thrombosis events (RR:1.35, 95% CI 0.86 to 2.12, I2 = 37%; χ2 test for heterogeneity, P = 0.19), or ECMO circuit/change (RR:0.90, 95% CI 0.48 to 1.71, I2 = 28%; χ2 test for heterogeneity, P = 0.75). Conclusion: Routine use of POC tests did not improve the main clinical outcomes beyond suggesting a diagnosis of surgical bleeding in ECMO patients.

Systematic review and meta-analysis of the clinical effectiveness of point-of-care testing for anticoagulation management during ECMO

Matteucci M.;
2021-01-01

Abstract

Study objective: Viscoelastic point-of-care (POC) tests are commonly used to provide prompt diagnosis of coagulopathy and allow targeted treatments in bleeding patients on ECMO. We evaluated the clinical effectiveness of point-of-care (POC) testing for anticoagulation management in patients on extracorporeal membrane oxygenation (ECMO). Design: Systematic review and meta-analysis. Eligible studies evaluating the use of thromboelastography- or thromboelastometry-guided algorithms, anti-factor Xa and platelet function testing were selected after screening the literature from July 1975 to January 2020. Setting: Patients on ECMO support. Patients: Anticoagulation management on ECMO patients. Interventions: Rotational thromboelastometry, thromboelastography, alone or combined with platelet function testing. Trials monitoring the anticoagulation effects during ECMO using an anti-factor Xa assay were included in the systematic review. Measurements: The primary outcomes were bleeding events, surgical revisions, thrombosis events and ECMO circuit change/failure. Secondary outcomes were blood-product transfusions, cerebrovascular accidents, mortality on ECMO, ECMO duration, intensive care unit and hospital discharge rates, and in-hospital mortality. Main results: Thirty-one trials enrolling 1684 participants were included in the systematic review. Four trials enrolling 547 subjects were included in the meta-analysis. The use of a POC testing device resulted in improved detection of surgical bleeding (RR: 0.68, 95% CI 0.49 to 0.94, I2 = 0%; χ2 test for heterogeneity, P = 0.02). The use of POC-guided algorithms did not affect bleeding (RR:0.78, 95% CI 0.58 to 1.04, I2 = 47%; χ2 test for heterogeneity, P = 0.09), thrombosis events (RR:1.35, 95% CI 0.86 to 2.12, I2 = 37%; χ2 test for heterogeneity, P = 0.19), or ECMO circuit/change (RR:0.90, 95% CI 0.48 to 1.71, I2 = 28%; χ2 test for heterogeneity, P = 0.75). Conclusion: Routine use of POC tests did not improve the main clinical outcomes beyond suggesting a diagnosis of surgical bleeding in ECMO patients.
2021
Anticoagulation; Bleeding; Extracorporeal membrane oxygenation; Point of care; Viscoelastic test; Anticoagulants; Blood Coagulation; Humans; Point-of-Care Testing; Treatment Outcome; Extracorporeal Membrane Oxygenation
Jiritano, F.; Fina, D.; Lorusso, R.; ten Cate, H.; Kowalewski, M.; Matteucci, M.; Serra, R.; Mastroroberto, P.; Serraino, G. F.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2130468
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact