Background: Dual-phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software are helpful tools for detecting arteries before planned endovascular interventions. Purpose: To evaluate the usefulness of DP-CBCT and AVD software in guiding the trans-arterial embolization (TAE) of challenging T2 lumbar endoleaks (T2-L-EL). Material and Methods: Ten patients with T2-L-EL were included in this study. The accuracy of DP-CBCT and the AVD software was defined by the ability to detect the endoleak and arterial feeding vessel, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software and the successful embolization of the endoleak. Clinical success was defined as the absence of recurrent endoleaks during follow-up and the stability of the sac diameter for persistent endoleaks. The total volume of iodinated contrast medium, overall procedure time, mean procedural radiation dose, and mean fluoroscopy time were recorded. Results: The EL was detected by DP-CBCT in all patients. The AVD software identified the feeding arterial branch in all cases. In one patient, the nidus of the endoleak was not reached due to the small caliber of the feeding artery, even though the software had clearly identified the vessel route. The mean contrast volume was 109 mL, the mean overall procedural time was 74.3 min. The mean procedural radiation dose was 140.97 Gy cm2, and the mean fluoroscopy time was 29.8 min. Conclusion: The use of DP-CBCT and the AVD software is feasible and may facilitate successful embolization in challenging occult T2-L-EL with complex vasculature.

Type 2 endoleaks in endovascular aortic repair: cone beam CT and automatic vessel detection to guide the embolization

Piacentino F.;Carrafiello G.
2018-01-01

Abstract

Background: Dual-phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software are helpful tools for detecting arteries before planned endovascular interventions. Purpose: To evaluate the usefulness of DP-CBCT and AVD software in guiding the trans-arterial embolization (TAE) of challenging T2 lumbar endoleaks (T2-L-EL). Material and Methods: Ten patients with T2-L-EL were included in this study. The accuracy of DP-CBCT and the AVD software was defined by the ability to detect the endoleak and arterial feeding vessel, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software and the successful embolization of the endoleak. Clinical success was defined as the absence of recurrent endoleaks during follow-up and the stability of the sac diameter for persistent endoleaks. The total volume of iodinated contrast medium, overall procedure time, mean procedural radiation dose, and mean fluoroscopy time were recorded. Results: The EL was detected by DP-CBCT in all patients. The AVD software identified the feeding arterial branch in all cases. In one patient, the nidus of the endoleak was not reached due to the small caliber of the feeding artery, even though the software had clearly identified the vessel route. The mean contrast volume was 109 mL, the mean overall procedural time was 74.3 min. The mean procedural radiation dose was 140.97 Gy cm2, and the mean fluoroscopy time was 29.8 min. Conclusion: The use of DP-CBCT and the AVD software is feasible and may facilitate successful embolization in challenging occult T2-L-EL with complex vasculature.
2018
automatic vessel detection software; Cone beam computed tomography (CBCT); trans-arterial embolization; type 2 lumbar endoleaks
Ierardi, A. M.; Pesapane, F.; Rivolta, N.; Fumarola, E. M.; Angileri, S. A.; Piacentino, F.; Carrafiello, G.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2135872
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact