The identification of mismatch repair deficient (dMMR) and microsatellite unstable (MSI) endometrial cancers (ECs) is important in screening, diagnosis, and therapeutic stratification of patients. We compared the diagnostic performance of 4 MSI molecular tests based on fragment length assay in capillary electrophoresis (OncoMate™ MSI assay, Promega) and in microcapillary electrophoresis (TapeStation 4200, Agilent); with high-resolution melting (HRM) analysis approaches (Idylla™ MSI Test, Biocartis; EasyPGX® ready MSI, Diatech Pharmacogenetics) on a series of 56 ECs, which was well characterized for MMR status with immunohistochemical approach (IHC, nonmolecular reference test). The concordance of fluorescence capillary electrophoresis with IHC (AUC 0.98) was higher respect to the other molecular methodologies. Otherwise, HRM approaches and microcapillary electrophoresis platform failed to detect MSI-ECs showing minimal microsatellite shifts. In conclusion, in colorectal site, several technologies are eligible for MSI test, whereas in ECs, MSI test should be based on fluorescent capillary electrophoresis as it identifies a higher proportion of cases that could be misdiagnosed with other strategies.

Critical aspects of microsatellite instability testing in endometrial cancer: a comparison study

Libera L.;Sahnane N.;De Luca C.;Russo G.;Sessa F.;Furlan D.
2022-01-01

Abstract

The identification of mismatch repair deficient (dMMR) and microsatellite unstable (MSI) endometrial cancers (ECs) is important in screening, diagnosis, and therapeutic stratification of patients. We compared the diagnostic performance of 4 MSI molecular tests based on fragment length assay in capillary electrophoresis (OncoMate™ MSI assay, Promega) and in microcapillary electrophoresis (TapeStation 4200, Agilent); with high-resolution melting (HRM) analysis approaches (Idylla™ MSI Test, Biocartis; EasyPGX® ready MSI, Diatech Pharmacogenetics) on a series of 56 ECs, which was well characterized for MMR status with immunohistochemical approach (IHC, nonmolecular reference test). The concordance of fluorescence capillary electrophoresis with IHC (AUC 0.98) was higher respect to the other molecular methodologies. Otherwise, HRM approaches and microcapillary electrophoresis platform failed to detect MSI-ECs showing minimal microsatellite shifts. In conclusion, in colorectal site, several technologies are eligible for MSI test, whereas in ECs, MSI test should be based on fluorescent capillary electrophoresis as it identifies a higher proportion of cases that could be misdiagnosed with other strategies.
2022
Capillary electrophoresis; Endometrial cancer; High-resolution melting; Microsatellite instability; Mismatch repair; MLH1 hypermethylation
Libera, L.; Sahnane, N.; Pepe, F.; Pisapia, P.; De Luca, C.; Russo, G.; Parente, P.; Covelli, C.; Chiaravalli, A. M.; Sessa, F.; Malapelle, U.; Furlan, D.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2139796
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact