Seismocardiogram (SCG) is the measure of the minute vibrations produced by the beating heart. We previously demonstrated that SCG, ECG and respiration could be recorded over the 24h during spontaneous behavior by a smart garment, the MagIC-SCG system. In the present case study we explored the feasibility of a beat-to-beat estimation of two indices of heart contractility, the Left Ventricular Ejection Time (LVET) and the electromechanical systole (QS2) from SCG and ECG recordings obtained by the MagIC-SCG device in one subject. We considered data collected during outdoor spontaneous behavior (while sitting in the metro and in the office) and in a laboratory setting (in supine and sitting posture, and during recovery after 100W and 140W cycling). LVET was estimated from SCG as the time interval between the opening and closure of the aortic valve, QS2 as the time interval between the Q wave of the ECG and the closure of the aortic valve. In every condition, LVET and QS2 could be estimated on a beat-to-beat basis from the SCG collected by the smart garment. LVET and QS2 are characterized by important beat-to-beat fluctuations, with standard deviations in the same order of magnitude of RR Interval. In all settings, spectral profiles are different for LVET, QS2 and RR Interval. This suggests that the biological mechanisms impinging on the heart exert a differentiated influence on the variability of each of these three indices.

Beat-to-beat estimation of LVET and QS2 indices of cardiac mechanics from wearable seismocardiography in ambulant subjects

Castiglioni P;
2013-01-01

Abstract

Seismocardiogram (SCG) is the measure of the minute vibrations produced by the beating heart. We previously demonstrated that SCG, ECG and respiration could be recorded over the 24h during spontaneous behavior by a smart garment, the MagIC-SCG system. In the present case study we explored the feasibility of a beat-to-beat estimation of two indices of heart contractility, the Left Ventricular Ejection Time (LVET) and the electromechanical systole (QS2) from SCG and ECG recordings obtained by the MagIC-SCG device in one subject. We considered data collected during outdoor spontaneous behavior (while sitting in the metro and in the office) and in a laboratory setting (in supine and sitting posture, and during recovery after 100W and 140W cycling). LVET was estimated from SCG as the time interval between the opening and closure of the aortic valve, QS2 as the time interval between the Q wave of the ECG and the closure of the aortic valve. In every condition, LVET and QS2 could be estimated on a beat-to-beat basis from the SCG collected by the smart garment. LVET and QS2 are characterized by important beat-to-beat fluctuations, with standard deviations in the same order of magnitude of RR Interval. In all settings, spectral profiles are different for LVET, QS2 and RR Interval. This suggests that the biological mechanisms impinging on the heart exert a differentiated influence on the variability of each of these three indices.
2013
978-0-8162-4464-5
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2145262
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 23
social impact