Background: The Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) regulation requires the establishment of Conditions of Use (CoU) for all exposure scenarios to ensure good communication of safe working practices. Setting CoU requires the risk assessment of all relevant Contributing Scenarios (CSs) in the exposure scenario. A new CS has to be created whenever an Operational Condition (OC) is changed, resulting in an excessive number of exposure assessments. An efficient solution is to quantify OC concentrations and to identify reasonable worst-case scenarios with probabilistic exposure modeling. Methods: Here, we appoint CoU for powder pouring during the industrial manufacturing of a paint batch by quantifying OC exposure levels and exposure determinants. The quantification was performed by using stationary measurements and a probabilistic Near-Field/Far-Field (NF/FF) exposure model. Work shift and OC concentration levels were quantified for pouring TiO 2 from big bags and small bags, pouring Micro Mica from small bags, and cleaning. The impact of exposure determinants on NF concentration level was quantified by (1) assessing exposure determinants correlation with the NF exposure level and (2) by performing simulations with different OCs. Results: Emission rate, air mixing between NF and FF and local ventilation were the most relevant exposure determinants affecting NF concentrations. Potentially risky OCs were identified by performing Reasonable Worst Case (RWC) simulations and by comparing the exposure 95 th percentile distribution with 10% of the occupational exposure limit value (OELV). The CS was shown safe except in RWC scenario (ventilation rate from 0.4 to 1.6 1/h, 100 m 3 room, no local ventilation, and NF ventilation of 1.6 m 3/min). Conclusions: The CoU assessment was considered to comply with European Chemicals Agency (ECHA) legislation and EN 689 exposure assessment strategy for testing compliance with OEL values. One RWC scenario would require measurements since the exposure level was 12.5% of the OELV.

Assessment of exposure determinants and exposure levels by using stationary concentration measurements and a probabilistic near-field/far-field exposure model

Spinazzè Andrea
Secondo
;
Borghi Francesca;
2021-01-01

Abstract

Background: The Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) regulation requires the establishment of Conditions of Use (CoU) for all exposure scenarios to ensure good communication of safe working practices. Setting CoU requires the risk assessment of all relevant Contributing Scenarios (CSs) in the exposure scenario. A new CS has to be created whenever an Operational Condition (OC) is changed, resulting in an excessive number of exposure assessments. An efficient solution is to quantify OC concentrations and to identify reasonable worst-case scenarios with probabilistic exposure modeling. Methods: Here, we appoint CoU for powder pouring during the industrial manufacturing of a paint batch by quantifying OC exposure levels and exposure determinants. The quantification was performed by using stationary measurements and a probabilistic Near-Field/Far-Field (NF/FF) exposure model. Work shift and OC concentration levels were quantified for pouring TiO 2 from big bags and small bags, pouring Micro Mica from small bags, and cleaning. The impact of exposure determinants on NF concentration level was quantified by (1) assessing exposure determinants correlation with the NF exposure level and (2) by performing simulations with different OCs. Results: Emission rate, air mixing between NF and FF and local ventilation were the most relevant exposure determinants affecting NF concentrations. Potentially risky OCs were identified by performing Reasonable Worst Case (RWC) simulations and by comparing the exposure 95 th percentile distribution with 10% of the occupational exposure limit value (OELV). The CS was shown safe except in RWC scenario (ventilation rate from 0.4 to 1.6 1/h, 100 m 3 room, no local ventilation, and NF ventilation of 1.6 m 3/min). Conclusions: The CoU assessment was considered to comply with European Chemicals Agency (ECHA) legislation and EN 689 exposure assessment strategy for testing compliance with OEL values. One RWC scenario would require measurements since the exposure level was 12.5% of the OELV.
2021
2021
https://open-research-europe.ec.europa.eu/articles/1-72
Conditions of Use; ECHA; EN 689; Inhalation exposure; Probabilistic model; REACH; Stationary measurements
Koivisto, A. J.; Spinazzè, Andrea; Verdonck, F.; Borghi, Francesca; Londahl, J.; Koponen, I. K.; Verpaele, S.; Jayjock, M.; Hussein, T.; Lopez de Ipina, J.; Arnold, S.; Furxhi, I.
File in questo prodotto:
File Dimensione Formato  
2021_Koivisto_assessment exposure determinants and leves probabilistic.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 2.59 MB
Formato Adobe PDF
2.59 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2146751
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? ND
social impact