Plenty of serologic tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed so far, thus documenting the importance of evaluating the relevant features of the immune response to this viral agent. The performance of these assays is currently under investigation. Amongst them, LIAISON® SARS-CoV-2 S1/S2 IgG by DiaSorin and Elecsys Anti-SARS-CoV-2 cobas® by Roche are currently used by laboratory medicine hospital departments in Italy and many other countries. In the present study, we firstly compared two serologic tests on serum samples collected at two different time points from 46 laboratory-confirmed coronavirus disease-2019 (COVID-19) subjects. Secondly, 85 negative serum samples collected before the SARS-CoV-2 pandemic were analyzed. Thirdly, possible correlations between antibody levels and the resulting neutralizing activity against a clinical isolate of SARS-CoV-2 were evaluated. Results revealed that both tests are endowed with low sensitivity on the day of hospital admission, which increased to 97.8% and 100% for samples collected after 15 days for DiaSorin and Roche tests, respectively. The specificity evaluated for the two tests ranges from 96.5% to 100%, respectively. Importantly, a poor direct correlation between antibody titers and neutralizing activity levels was evidenced in the present study. These data further shed light on both potentials and possible limitations related to SARS-CoV-2 serology. In this context, great efforts are still necessary for investigating antibody kinetics to develop novel diagnostic algorithms. Moreover, further investigations on the role of neutralizing antibodies and their correlate of protection will be of paramount importance for the development of effective vaccines.

Weak correlation between antibody titers and neutralizing activity in sera from SARS-CoV-2 infected subjects

Mancini, Nicasio;Clementi, Massimo;
2021-01-01

Abstract

Plenty of serologic tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed so far, thus documenting the importance of evaluating the relevant features of the immune response to this viral agent. The performance of these assays is currently under investigation. Amongst them, LIAISON® SARS-CoV-2 S1/S2 IgG by DiaSorin and Elecsys Anti-SARS-CoV-2 cobas® by Roche are currently used by laboratory medicine hospital departments in Italy and many other countries. In the present study, we firstly compared two serologic tests on serum samples collected at two different time points from 46 laboratory-confirmed coronavirus disease-2019 (COVID-19) subjects. Secondly, 85 negative serum samples collected before the SARS-CoV-2 pandemic were analyzed. Thirdly, possible correlations between antibody levels and the resulting neutralizing activity against a clinical isolate of SARS-CoV-2 were evaluated. Results revealed that both tests are endowed with low sensitivity on the day of hospital admission, which increased to 97.8% and 100% for samples collected after 15 days for DiaSorin and Roche tests, respectively. The specificity evaluated for the two tests ranges from 96.5% to 100%, respectively. Importantly, a poor direct correlation between antibody titers and neutralizing activity levels was evidenced in the present study. These data further shed light on both potentials and possible limitations related to SARS-CoV-2 serology. In this context, great efforts are still necessary for investigating antibody kinetics to develop novel diagnostic algorithms. Moreover, further investigations on the role of neutralizing antibodies and their correlate of protection will be of paramount importance for the development of effective vaccines.
2021
2020
https://onlinelibrary.wiley.com/doi/10.1002/jmv.26605
COVID-19 diagnostic assays; SARS-CoV-2 serology; neutralizing activity
Criscuolo, Elena; Diotti, Roberta A; Strollo, Marta; Rolla, Serena; Ambrosi, Alessandro; Locatelli, Massimo; Burioni, Roberto; Mancini, Nicasio; Clementi, Massimo; Clementi, Nicola
File in questo prodotto:
File Dimensione Formato  
jmv.26605CR_CN.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 2.01 MB
Formato Adobe PDF
2.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2148976
Citazioni
  • ???jsp.display-item.citation.pmc??? 41
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 43
social impact