: • The origins and courses of the coronary arteries can be detected on TTE. • Three “echo-signs” can detect an anomalous origin of the circumflex coronary artery. • A significant stenosis in the anomalous left circumflex artery can be detected on TTE.

Three Echocardiographic Signs to Identify Anomalous Origin of the Circumflex Coronary Artery from the Right Sinus of Valsalva: A Case Report

Mancinelli, Antonella
Primo
;
Golino, Michele
;
Miglierina, Emilio;My, Ilaria;Crippa, Matteo;De Ponti, Roberto
Ultimo
2020-01-01

Abstract

: • The origins and courses of the coronary arteries can be detected on TTE. • Three “echo-signs” can detect an anomalous origin of the circumflex coronary artery. • A significant stenosis in the anomalous left circumflex artery can be detected on TTE.
2020
2020
Cardiovascular disease; Coronary angiography; Coronary circulation; Coronary vessel anomaly; Echocardiography