Objective The identification of deep myometrial invasion (DMI) represents a fundamental aspect in patients with endometrial cancer (EC) for accurate disease staging. It can be detected on MRI using T2-weighted (T2-w), diffusion weighted (DWI) and dynamic contrast enhanced sequences (DCE). Aim of the study was to perform a multi-reader evaluation of such sequences to identify the most accurate and its reliability for the best protocol. Methods In this multicenter retrospective study, MRI were independently evaluated by 4 radiologists (2 senior and 2 novice) with a sequence-based approach to identify DMI. The performance of the entire protocol was also evaluated. A comparison between the different sequences assessed by the same reader was performed using receiver operating curve and post-hoc analysis. Intraclass Correlation Coefficient (ICC) was used to assess inter- and intra-observer variability. Results A total of 92 patients were included. The performance of the readers did not show significant differences among DWI, DCE and the entire protocol. For only one senior radiologist, who reached the highest diagnostic accuracy with the entire protocol (82,6 %), both DWI (p = 0,0197) and entire protocol (p = 0,0039) were found significantly superior to T2-w. The highest inter-observer agreement was obtained with the entire protocol by expert readers (ICC = 0,77). Conclusions For the detection of DMI, the performances of DWI and DCE alone and that of a complete protocol do not significantly differ, even though the latter ensures the highest reliability particularly for expert readers. In cases in which T2-w and DWI are consistent, an unenhanced protocol could be proposed.
MRI to assess deep myometrial invasion in patients with endometrial cancer: a multi-reader study to evaluate the diagnostic role of different sequences
Travaglino, Antonio;
2021-01-01
Abstract
Objective The identification of deep myometrial invasion (DMI) represents a fundamental aspect in patients with endometrial cancer (EC) for accurate disease staging. It can be detected on MRI using T2-weighted (T2-w), diffusion weighted (DWI) and dynamic contrast enhanced sequences (DCE). Aim of the study was to perform a multi-reader evaluation of such sequences to identify the most accurate and its reliability for the best protocol. Methods In this multicenter retrospective study, MRI were independently evaluated by 4 radiologists (2 senior and 2 novice) with a sequence-based approach to identify DMI. The performance of the entire protocol was also evaluated. A comparison between the different sequences assessed by the same reader was performed using receiver operating curve and post-hoc analysis. Intraclass Correlation Coefficient (ICC) was used to assess inter- and intra-observer variability. Results A total of 92 patients were included. The performance of the readers did not show significant differences among DWI, DCE and the entire protocol. For only one senior radiologist, who reached the highest diagnostic accuracy with the entire protocol (82,6 %), both DWI (p = 0,0197) and entire protocol (p = 0,0039) were found significantly superior to T2-w. The highest inter-observer agreement was obtained with the entire protocol by expert readers (ICC = 0,77). Conclusions For the detection of DMI, the performances of DWI and DCE alone and that of a complete protocol do not significantly differ, even though the latter ensures the highest reliability particularly for expert readers. In cases in which T2-w and DWI are consistent, an unenhanced protocol could be proposed.File | Dimensione | Formato | |
---|---|---|---|
MRI to assess deep myometrial invasion in patients with endometrial cancer a multi-reader study to evaluate the diagnostic role of different sequences.pdf
non disponibili
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
3.08 MB
Formato
Adobe PDF
|
3.08 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.