BACKGROUND: Despite the well-known second trimester ultrasound signs, current possibilities of in utero surgical repair of open spina bifida require a timely detection of the spine defect. OBJECTIVE: To evaluate the diagnostic accuracy of the ratio between brain stem (BS) diameter and its distance to the occipital bone (BSOB) (BS/BSOB ratio) in the detection of fetuses with open spina bifida at first trimester ultrasound. METHODS: A systematic review and meta-analysis of diagnostic accuracy was performed by searching seven electronic databases from their inception to February 2019 for all studies assessing the association between BS/BSOB ratio and diagnosis of spine bifida. Diagnostic accuracy of BS/BSOB ratio in prenatal diagnosis of spine bifida was assessed as sensitivity, specificity, positive and negative likelihood ratios (LR + and LR-), and area under the curve (AUC) on SROC curves. RESULTS: Four studies, including 17,598 fetuses with 23 cases of open spina bifida, were included in the meta-analysis. BS/BSOB ratio showed pooled sensitivity of 0.70 (95% CI 0.47-0.87; I2 = 78.3%), specificity of 1.00 (95% CI 0.99-1.0; I2 = 99.2%), LR + and LR- of 51.44 (95% CI 9.53-277.64; I2 = 85.5%) and 0.23 (95% CI 0.04-1.17; I2 = 64.8%), respectively, and an AUC of 0.9649. CONCLUSION: First trimester BS/BSOB ratio has a high diagnostic accuracy in detecting fetuses with open spina bifida.
First trimester detection of fetal open spina bifida using BS/BSOB ratio
Travaglino A.;
2020-01-01
Abstract
BACKGROUND: Despite the well-known second trimester ultrasound signs, current possibilities of in utero surgical repair of open spina bifida require a timely detection of the spine defect. OBJECTIVE: To evaluate the diagnostic accuracy of the ratio between brain stem (BS) diameter and its distance to the occipital bone (BSOB) (BS/BSOB ratio) in the detection of fetuses with open spina bifida at first trimester ultrasound. METHODS: A systematic review and meta-analysis of diagnostic accuracy was performed by searching seven electronic databases from their inception to February 2019 for all studies assessing the association between BS/BSOB ratio and diagnosis of spine bifida. Diagnostic accuracy of BS/BSOB ratio in prenatal diagnosis of spine bifida was assessed as sensitivity, specificity, positive and negative likelihood ratios (LR + and LR-), and area under the curve (AUC) on SROC curves. RESULTS: Four studies, including 17,598 fetuses with 23 cases of open spina bifida, were included in the meta-analysis. BS/BSOB ratio showed pooled sensitivity of 0.70 (95% CI 0.47-0.87; I2 = 78.3%), specificity of 1.00 (95% CI 0.99-1.0; I2 = 99.2%), LR + and LR- of 51.44 (95% CI 9.53-277.64; I2 = 85.5%) and 0.23 (95% CI 0.04-1.17; I2 = 64.8%), respectively, and an AUC of 0.9649. CONCLUSION: First trimester BS/BSOB ratio has a high diagnostic accuracy in detecting fetuses with open spina bifida.File | Dimensione | Formato | |
---|---|---|---|
186 bs bsob spina bifida - Archives DOI - Sirico.pdf
non disponibili
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
1.68 MB
Formato
Adobe PDF
|
1.68 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.