One-step nucleic acid amplification (OSNA) is used to intraoperatively detect sentinel lymph node metastases in breast cancer. OSNA has also been proposed in endometrial cancer, but evidence in this regard is unclear to define the diagnostic accuracy of OSNA in detecting lymph node metastases in endometrial cancer. A systematic review and meta-analysis was performed by searching 8 electronic databases from their inception to March 2019 for studies testing the diagnostic accuracy of OSNA in detecting sentinel lymph node metastasis in endometrial cancer. Pathologic ultrastaging was the reference standard. Sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-), diagnostic odds ratio (DOR) and area under the curve (AUC) on SROC curve were calculated. Four studies with 237 patients and 691 lymph nodes were included. OSNA showed sensitivity = 0.88, specificity = 0.93, LR + =17.95, LR- = 0.15, DOR = 191.23 and high diagnostic accuracy (AUC = 0.959). OSNA appears as a highly accurate tool for intraoperative assessment of sentinel lymph node in endometrial cancer.

Accuracy of one-step nucleic acid amplification in detecting lymph node metastases in endometrial cancer

Travaglino A.;
2020-01-01

Abstract

One-step nucleic acid amplification (OSNA) is used to intraoperatively detect sentinel lymph node metastases in breast cancer. OSNA has also been proposed in endometrial cancer, but evidence in this regard is unclear to define the diagnostic accuracy of OSNA in detecting lymph node metastases in endometrial cancer. A systematic review and meta-analysis was performed by searching 8 electronic databases from their inception to March 2019 for studies testing the diagnostic accuracy of OSNA in detecting sentinel lymph node metastasis in endometrial cancer. Pathologic ultrastaging was the reference standard. Sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-), diagnostic odds ratio (DOR) and area under the curve (AUC) on SROC curve were calculated. Four studies with 237 patients and 691 lymph nodes were included. OSNA showed sensitivity = 0.88, specificity = 0.93, LR + =17.95, LR- = 0.15, DOR = 191.23 and high diagnostic accuracy (AUC = 0.959). OSNA appears as a highly accurate tool for intraoperative assessment of sentinel lymph node in endometrial cancer.
2020
2019
Endometrial cancer; Intraoperative; OSNA; Sentinel lymph node; Tailored medicine; Ultrastaging
Raffone, A.; Travaglino, A.; Santoro, A.; Esposito, I.; Angelico, G.; Spadola, S.; Zannoni, G. F.
File in questo prodotto:
File Dimensione Formato  
26. EC OSNA.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2165797
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 33
social impact