The IEE Passive-On project has drafted a proposal to adapt that Standard to the conditions that characterize Southern Europe, which is described in this paper together with its rationale. Compared with the original definition, one of the main changes is the introduction of explicit requirements on internal comfort during summer, in parallel to a limit to energy needs for cooling. The dynamic simulations conducted to test the new definition of the Standard in the context of Southern Italy (e.g. Palermo) show that the requirements identified by the Passivhaus Standard can be met by simplifying the envelope technologies (e.g. relaxing air-tightness design value) used in the context of Central Europe and adopting passive cooling strategies appropriately adjusted. Some simplifications of the ventilation system can be compensated by an increased role of thermal insulation of the building envelope and some of the choices can make energy needs tend to zero. In accordance with EN15251, thermal comfort is characterized according to Fanger’s PMV in cases where mechanical cooling is still required for peak situations, and according to the adaptive model where no mechanical cooling is required.

Passive house optimization for Southern Italy based on the “New Passivhaus Standard”

S. Carlucci
2009-01-01

Abstract

The IEE Passive-On project has drafted a proposal to adapt that Standard to the conditions that characterize Southern Europe, which is described in this paper together with its rationale. Compared with the original definition, one of the main changes is the introduction of explicit requirements on internal comfort during summer, in parallel to a limit to energy needs for cooling. The dynamic simulations conducted to test the new definition of the Standard in the context of Southern Italy (e.g. Palermo) show that the requirements identified by the Passivhaus Standard can be met by simplifying the envelope technologies (e.g. relaxing air-tightness design value) used in the context of Central Europe and adopting passive cooling strategies appropriately adjusted. Some simplifications of the ventilation system can be compensated by an increased role of thermal insulation of the building envelope and some of the choices can make energy needs tend to zero. In accordance with EN15251, thermal comfort is characterized according to Fanger’s PMV in cases where mechanical cooling is still required for peak situations, and according to the adaptive model where no mechanical cooling is required.
2009
AA.VV.
ECEEE Summer Study proceedings
9789163344541
ECEEE Summer Study: ACT! INNOVATE! DELIVER! REDUCING ENERGY DEMAND SUSTAINABLY
La Colle sur Loup, France
01/06/2009 - 06/06/2009
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2177231
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact