Precast concrete structures are recognized among the structural typologies that may mostly suffer from progressive collapse as a consequence of local unpredicted damage, also due to past accidents occurred in buildings employing old precast technologies neglecting the basic robustness criteria and characterized by poorly detailed and/or executed joints and connections. Although vertical ties may relatively easily be provided in both frame and wall panel structures by employing ductile connection devices, dry-assembled precast systems avoiding concrete pouring in the whole superstructure typically struggle to provide horizontal ties as strong as required by the current standards concerning progressive collapse, in which they are not fully framed yet. Nevertheless, these systems may exploit alternative sources of robustness to stop collapse progression arising from their structural arrangement, the shape of the slab elements employed, and the slab mechanical connections. This article presents the results of a numerical investigation focused on the structural behavior of a dry-assembled precast floor system consisting of prestressed box-section slab elements employed in either wall panel or coupled wall-frame structural systems following the loss of one or multiple primary load-bearing vertical elements. Nonlinear static simulations of different loss scenarios occurring in prototypes of 100-m-tall high-rise buildings were carried out based upon spread plasticity modeling of the structural elements and experimentally calibrated nonlinear behavior of mechanical connections.

Robustness of Dry-Assembled Precast Wall and Coupled Wall-Frame High-Rise Structures With Voided Prestressed Slabs

Lago Bruno
;
2024-01-01

Abstract

Precast concrete structures are recognized among the structural typologies that may mostly suffer from progressive collapse as a consequence of local unpredicted damage, also due to past accidents occurred in buildings employing old precast technologies neglecting the basic robustness criteria and characterized by poorly detailed and/or executed joints and connections. Although vertical ties may relatively easily be provided in both frame and wall panel structures by employing ductile connection devices, dry-assembled precast systems avoiding concrete pouring in the whole superstructure typically struggle to provide horizontal ties as strong as required by the current standards concerning progressive collapse, in which they are not fully framed yet. Nevertheless, these systems may exploit alternative sources of robustness to stop collapse progression arising from their structural arrangement, the shape of the slab elements employed, and the slab mechanical connections. This article presents the results of a numerical investigation focused on the structural behavior of a dry-assembled precast floor system consisting of prestressed box-section slab elements employed in either wall panel or coupled wall-frame structural systems following the loss of one or multiple primary load-bearing vertical elements. Nonlinear static simulations of different loss scenarios occurring in prototypes of 100-m-tall high-rise buildings were carried out based upon spread plasticity modeling of the structural elements and experimentally calibrated nonlinear behavior of mechanical connections.
2024
2024
high-rise buildings; mechanical connections; precast concrete; progressive collapse; risk analysis; robustness
Bruno, Lago; Gajera, K; Martinelli, P
File in questo prodotto:
File Dimensione Formato  
Structural Design Tall Build - 2024 - Dal Lago - Robustness of Dry‐Assembled Precast Wall and Coupled Wall‐Frame High‐Rise.pdf

accesso aperto

Descrizione: paper
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 10.68 MB
Formato Adobe PDF
10.68 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2185051
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact