Objective: The primary aim of this study was to assess the factors associated with bilateral mapping failure in patients with apparent early-stage cervical cancer undergoing sentinel lymph node (SLN) biopsy using indocyanine green (ICG). Secondary aims were sensitivity, negative predictive value and lymph node recurrence. Methods: Retrospective multi-center study. Patients with cervical cancer apparent FIGO stage IA1 to IIA2, treated with primary surgery between 04/2015 and 12/2023 and undergoing SLN mapping attempt with ICG injection, were included. Appropriate statistical analysis was performed to assess study endpoints. Timeframe was divided in first period 04/2015-12/2019 and second period 01/2020-12/2023. Results: 618 patients were included. Bilateral SLN mapping was achieved in 531 (85.9 %) women (36 of them, 5.8 %, underwent cervical re-injection of ICG). SLN unilateral mapping and mapping failure was observed in 71 (11.5 %) and 16 (2.6 %), respectively. The sensitivity, negative predictive value and accuracy were 85.9 %, 98.1 % and 98.3 %, respectively. False negative rate was 4/68 (5.9 %) in patients with unilateral mapping versus 6/ 316 (1.9 %) in those with bilateral mapping (p = 0.061). BMI>30 (p = 0.001) and pathologic tumor diameter >20 mm (p = 0.023) were the only factors independently associated with bilateral SLN mapping failure. ICG reinjection increased the rate of bilateral SLN detection from 81.3 % to 85.9 %. The rate of bilateral detection was 82.8 % versus 88.3 % in the first versus second study period, respectively (p = 0.061). 3-year DFS and OS in all patients were 89.7 % and 98.2 %, respectively. Seven patients (1.2 %) had lymph node recurrence in the group of any SLN mapping versus 1 (6.3 %) in no mapping group (p = 0.190). Conclusion: High BMI and larger tumors were associated with bilateral SLN mapping failure using ICG. The ICG cervical re-injection increased the rate of bilateral mapping. No lymph node recurrence difference was found in patients undergoing SLN mapping versus patients with mapping failure.

Factors associated with bilateral sentinel lymph node mapping failure using indocyanine green in patients with apparent early-stage cervical cancer: An Italian retrospective multi-center study

Casarin J.;
2025-01-01

Abstract

Objective: The primary aim of this study was to assess the factors associated with bilateral mapping failure in patients with apparent early-stage cervical cancer undergoing sentinel lymph node (SLN) biopsy using indocyanine green (ICG). Secondary aims were sensitivity, negative predictive value and lymph node recurrence. Methods: Retrospective multi-center study. Patients with cervical cancer apparent FIGO stage IA1 to IIA2, treated with primary surgery between 04/2015 and 12/2023 and undergoing SLN mapping attempt with ICG injection, were included. Appropriate statistical analysis was performed to assess study endpoints. Timeframe was divided in first period 04/2015-12/2019 and second period 01/2020-12/2023. Results: 618 patients were included. Bilateral SLN mapping was achieved in 531 (85.9 %) women (36 of them, 5.8 %, underwent cervical re-injection of ICG). SLN unilateral mapping and mapping failure was observed in 71 (11.5 %) and 16 (2.6 %), respectively. The sensitivity, negative predictive value and accuracy were 85.9 %, 98.1 % and 98.3 %, respectively. False negative rate was 4/68 (5.9 %) in patients with unilateral mapping versus 6/ 316 (1.9 %) in those with bilateral mapping (p = 0.061). BMI>30 (p = 0.001) and pathologic tumor diameter >20 mm (p = 0.023) were the only factors independently associated with bilateral SLN mapping failure. ICG reinjection increased the rate of bilateral SLN detection from 81.3 % to 85.9 %. The rate of bilateral detection was 82.8 % versus 88.3 % in the first versus second study period, respectively (p = 0.061). 3-year DFS and OS in all patients were 89.7 % and 98.2 %, respectively. Seven patients (1.2 %) had lymph node recurrence in the group of any SLN mapping versus 1 (6.3 %) in no mapping group (p = 0.190). Conclusion: High BMI and larger tumors were associated with bilateral SLN mapping failure using ICG. The ICG cervical re-injection increased the rate of bilateral mapping. No lymph node recurrence difference was found in patients undergoing SLN mapping versus patients with mapping failure.
2025
Cervical cancer; Detection rate; Indocyanine green; Mapping; Reinjection; Sentinel lymph node
Bizzarri, N.; Schivardi, G.; Di Martino, G.; Antonacci, A.; Querleu, D.; Pedone Anchora, L.; Ferrandina, G.; Fedele, C.; Carbone, V.; Casarin, J.; Bud...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2192651
 Attenzione

L'Ateneo sottopone a validazione solo i file PDF allegati

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact