This prospective clinical study evaluated the survival rate and the implant-crown success of 201 direct laser metal forming (DLMF) implants in different clinical applications, after short-term follow-up of functional loading. At the 1-year scheduled follow-up examination, several clinical, radiographic, and prosthetic parameters were assessed. Success criteria included absence of pain, sensitivity, suppuration, exudation; absence of implant mobility; absence of continuous peri-implant radiolucency, DIB <1.5 mm; absence of prosthetic complications at the implant-abutment interface. A total of 201 implants (106 maxilla, 95 mandible) were inserted in 62 patients (39 males, 23 females; aged between 26 and 65 years) in eight different clinical centers. The sites included anterior (n = 79) and posterior (n = 122) implants. The overall implant survival rate was 99.5\%, with one implant loss (maxilla: 99.0\%, 1 implant failure; mandible: 100.0\%, no implant failures). The mean DIB was 0.4 ± 0.2 mm. Among the survived implants (200), five did not fulfill the success criteria, giving an implant-crown success of 97.5\%. This 1-year follow-up prospective clinical study gives evidence of very high survival (99.5\%) and success (97.5\%) rates using DLMF implants.
Prospective clinical evaluation of 201 direct laser metal forming implants: results from a 1-year multicenter study.
MANGANO, CARLO;MACCHI, ALDO
2012-01-01
Abstract
This prospective clinical study evaluated the survival rate and the implant-crown success of 201 direct laser metal forming (DLMF) implants in different clinical applications, after short-term follow-up of functional loading. At the 1-year scheduled follow-up examination, several clinical, radiographic, and prosthetic parameters were assessed. Success criteria included absence of pain, sensitivity, suppuration, exudation; absence of implant mobility; absence of continuous peri-implant radiolucency, DIB <1.5 mm; absence of prosthetic complications at the implant-abutment interface. A total of 201 implants (106 maxilla, 95 mandible) were inserted in 62 patients (39 males, 23 females; aged between 26 and 65 years) in eight different clinical centers. The sites included anterior (n = 79) and posterior (n = 122) implants. The overall implant survival rate was 99.5\%, with one implant loss (maxilla: 99.0\%, 1 implant failure; mandible: 100.0\%, no implant failures). The mean DIB was 0.4 ± 0.2 mm. Among the survived implants (200), five did not fulfill the success criteria, giving an implant-crown success of 97.5\%. This 1-year follow-up prospective clinical study gives evidence of very high survival (99.5\%) and success (97.5\%) rates using DLMF implants.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.