The remarkable value of endobronchial ultrasound-transbronchial needle aspiration (EBUSTBNA) for mediastinal staging of non-small cell lung cancer (NSCLC) is recognized worldwide. Reports from different centers however show considerable variation of EBUS-TBNA performance in terms of diagnostic yield, sensitivity and negative predictive value (NPV). Interpretation of EBUSTBNA diagnostic efficacy requires clarifying whether the technique is used for purely diagnostic purpose or mediastinal staging, recognizing that different study groups may be inherently heterogeneous and that numerous factors may impact on the procedure outcomes. Review of these factors indicates that the prevalence of N2/N3 disease, the thoroughness of mediastinal sampling and > 3 needle passes per target lymph node (LN) [in the absence of rapid on-site eva luation (ROSE)] influence the procedure outcomes, while many details in the sample preparation technique are unlikely to impact on the results and should be left to the proceduralists' preference. Generalized use of a standardized database for prospective collection of relevant EBUS-TBNA data would allow reporting institutional results by subgroups of N2/N3 disease prevalence and thoroughness of staging, and would help establishing quality standards for the procedure.

Endobronchial ultrasound-transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: Variability of results and perspectives

CATTONI, MARIA ANGELA;DOMINIONI, LORENZO
2017-01-01

Abstract

The remarkable value of endobronchial ultrasound-transbronchial needle aspiration (EBUSTBNA) for mediastinal staging of non-small cell lung cancer (NSCLC) is recognized worldwide. Reports from different centers however show considerable variation of EBUS-TBNA performance in terms of diagnostic yield, sensitivity and negative predictive value (NPV). Interpretation of EBUSTBNA diagnostic efficacy requires clarifying whether the technique is used for purely diagnostic purpose or mediastinal staging, recognizing that different study groups may be inherently heterogeneous and that numerous factors may impact on the procedure outcomes. Review of these factors indicates that the prevalence of N2/N3 disease, the thoroughness of mediastinal sampling and > 3 needle passes per target lymph node (LN) [in the absence of rapid on-site eva luation (ROSE)] influence the procedure outcomes, while many details in the sample preparation technique are unlikely to impact on the results and should be left to the proceduralists' preference. Generalized use of a standardized database for prospective collection of relevant EBUS-TBNA data would allow reporting institutional results by subgroups of N2/N3 disease prevalence and thoroughness of staging, and would help establishing quality standards for the procedure.
2017
http://jtd.amegroups.com/article/download/13474/pdf
Diagnostic performance; Endobronchial ultrasound-transbronchial needle aspiration (EBUS-TBNA); Lung cancer; Mediastinal staging; Pulmonary and Respiratory Medicine
Nardecchia, Elisa; Cattoni, MARIA ANGELA; Dominioni, Lorenzo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11383/2064425
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 5
social impact